Component response time |
20 ms |
Overload current |
3.2 A |
Short circuit protection |
10 A rated device |
DHCP timeout |
Ethernet port: 30 s |
Web server |
Embedded web server |
Contactor size |
12 A safety contactor |
Safety |
Hardwired Safety (STO) |
Overvoltage category |
Control circuit: III per IEC |
Rated operational current |
Power circuit: 2.5 A maximum |
Product type |
Reversing starter |
Rated impulse voltage |
Power circuit: 6 kV |
IP address |
Ethernet port: DHCP enabled by default |
Average probability of dangerous failure |
MTTF for uncontrolled stop: 6.0E-9 (1/h) |
Ports |
Ethernet port: embedded switch with 2 ports |
Rated input operation voltage |
Sourced from control circuit (A3/A2): 24V DC |
Input OFF-state current |
Sourced from control circuit (A3/A3): <1.5 mA |
Input OFF-state voltage |
Sourced from control circuit (A3/A3): 0…5V DC |
Module inrush current |
EtherNet/IP version: 1.09 A (A1/A2 with HOA) |
Module steady current |
EtherNet/IP version: 0.3 A (A3/A2 without HOA) |
Total control power (running) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA) |
Input ON-state voltage |
Sourced from control circuit (A3/A3): 10…26V DC |
Operating frequency |
Power circuit: 50/60 Hz |
Input ON-state current |
Sourced from control circuit (A3/A3): 7.2mA @ 24V DC |
Ethernet receptacles |
Ethernet port: 2 D-coded, 4-pin female M12 connectors |
Option 1 |
Status only keypad |
Number of contacts |
Output ratings – sourced from control circuit (A1/A2): 2 |
Voltage status only |
Sensor source: 11…26.4V DC from unswitched power (A3-A2) |
Trip rating |
120% of full load current (FLC) setting |
Type of current |
Output ratings – sourced from control circuit (A1/A2): 24 DC |
Input compatibility |
Sourced from control circuit (A3/A3): IEC 61131-2 per IEC |
Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
ON-state voltage, max |
Output ratings – sourced from control circuit (A1/A2): 1.5V DC |
Contact rating |
SI – SM1 and SM2 (24V DC): DC-12 L/R, 1 ms resistive, 6 A |
Rated output operation voltage |
Output ratings – sourced from control circuit (A1/A2): 26.4V DC |
Insulation voltage |
Power circuit: rated 600V |
Communication rate |
Ethernet port: 10/100 Mbs with auto negotiate half duplex and full duplex |
Dielectric withstand |
Power circuit: 2500V AC per IEC |
Type of contacts |
Output ratings – sourced from control circuit (A1/A2): normally open (N.O.) |
SO – P/M |
SI – SM1 and SM2 (24V DC): 3 W/0.125 A per contactor (two safety contactors) |
Current available |
Sensor source: 50 mA maximum per input, 200 mA for any single point |
Type of control circuit |
Output ratings – sourced from control circuit (A1/A2): solid state sourcing output |
Conventional thermal current (Ith) |
Output ratings – sourced from control circuit (A1/A2): 0.5 A each, 1 A maximum combined |
Circuit breaker operational current rating, max |
60 A @ 600Y/347V |
RMS symmetrical amperes |
65 kA @ 600Y/347V |
Rated operation voltage |
Power circuit: 200…575V |
3-phase power/motor cable connection |
Control and 3-phase power, male receptacle with motor cable |
Input filter – software selectable |
Sourced from control circuit (A3/A3): settable from 0…64 ms in 1 ms increments (ON to OFF) |
Fuse operational current rating, max |
30 A @ 600Y/347V |
Total control power (pick up) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA) |
Peak output current |
Output ratings – sourced from control circuit (A1/A2): current limited 2-8 A (5 A nominal) @ 24V DC |
Trip class |
Class 10, 15, 20 |
Operational power rating |
Reversing starters – IP67/NEMA Type 4: 1.5Hp @ 575V AC, 60 Hz |
Data |
Ethernet port: Transported over both TCP and UDP, Minimum of 500 I/O packets/s (pps), Supports up to 150 concurrent TCP sockets |
Input frequency response, max |
Sourced from control circuit (A3/A3): 200 Hz (DeviceLogix response is greater than 200 Hz. Network response depends on control system network performance.) |
Device connections |
TCP port supports 5 concurrent incoming connections |
Number of digital inputs |
4 |
Number of digital outputs |
2 |
Application in industrial area permitted |
True |
Supporting protocol for EtherNet/IP |
True |
Mains frequency |
50/60 Hz |
MTTFd years |
100 year |
Short circuit protection device (SCPD) |
Type 1 |
Short circuit rating |
30 kA |
Disconnect |
Motor disconnect |
Conection type |
Quick disconnects |
Utilization category |
Power circuit: AC-3 per IEC |
Security |
Web server: login and password configurable |
Configuration |
Web server: status, diagnostics and configuration tabs |
E-mail |
Web server: support simple mail transfer protocol (SMTP) |
Off-state leakage current, max |
Output ratings – sourced from control circuit (A1/A2): 10 µA |
Blocking voltage, max |
Output ratings – sourced from control circuit (A1/A2): 35V DC |
Contact type |
SI – SM1 and SM2 (24V DC): IEC 60947-5-1 Annex L – mechanically |
Fault recovery |
DLR: ring recovery time is less than 3 ms for a 50 node network |
DC control voltage |
EtherNet/IP version: 24V DC (A1/A2, A3/A2, without and without HOA) |
Device level ring |
Beacon-based performance including IEEE 1588 end to end transparent clock |
Load types |
Output ratings – sourced from control circuit (A1/A2): resistive or light inductive |
Surge suppression |
Output ratings – sourced from control circuit (A1/A2): integrated diode, clA @ 35V DC |
Cycle rate, max |
Output ratings – sourced from control circuit (A1/A2): 30 ops/minute capacitive and inductive loads |
Thermo-protection |
Output ratings – sourced from control circuit (A1/A2): integrated short circuit and over current protection |