Technical Specifications

Mechanical

Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Altitude, max 3000 m of installation site
Protection class Contactor main contact: IP2X (100-E40…E96 meet IP2X when used with 100-ESC…terminal shrouds.)

Electrical

Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Rated control supply voltage at DC 100 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 8 kV
Operating time, closing delay 42 ms
Operating time, opening delay 17 ms
Optional overload relays Electronic
Rated isolation voltage (Ui) 600V per UL, CSA
Function Non-reversing contactor
Standard coil, pick-up 40VA/40 W @ 100…250V AC/DC
Standard coil, hold-in 4VA/2 W @ 100…250V AC/DC
General purpose current (enclosed) 80 A @ 600V per UL/CSA
FLA 115 A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed) 92 A @ 200-208V, 3-phase per UL/CSA
LRA 690 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
Electromagnetic compatibility IEC 60947-1 – Environment A and B (100-E09…E38 only.)
Operating limits, dropout (≤0.60) x Us @ DC control
Rating for switching AC motors 3-poles: 75 Hp @ 575V, AC-2, AC-3 (60 Hz)
Operating limits, pick-up (0.85…1.1) x Us @ 50/60 Hz
MCCB current rating Type 2 (per IEC 60947-4-1): 880 A @ 400 V, 70 kA available fault current
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 160 A @ 400 V, 100 kA available fault current
Rated voltage (Ue) 24V, 48V, 110V, 220V, 440V DC
Rated operational current and power 56 A @ 115V AC, 500000 electrical operations, 1-phase per UL/CSA elevator duty
Coil voltage 100 to 250V AC/DC
Switching of lighting loads Tungsten lamps: 115 A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200 A @ 600V, 10 kA available fault current
Rated operational current (Ie) 96 A @ 440V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200 A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250 A @ 600V, 50 kA available fault current
Switching of power transformers Apparent power: 87 kVA @ 480V, 60 Hz (n = 20)
Rated operational power (Pe) 93 kW @ 415V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
Switching of DC loads 3-poles in series: 130 A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-or front-mount auxiliary contacts, Mechanical interlocks, IP20 terminal shields, Connecting bars
Features Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials

Environmental

Climatic withstand Category B according to IEC 60947-1, annex Q
Ambient temperature Storage: -40…+70 (-40…+158)

Certification

Coil insulation class Class F per IEC 60947-4-1
Peso 1.297 kg
Dimensiones 14.98 × 14.98 × 10.41 cm
Marcas

Allen-Bradley

Marca

Allen-Bradley

Documentation

RESOURCE PUBLICATION NUMBER
Technical Data 100-TD013

Customers reviews

There are no reviews yet.

Be the first to review “100-E96KD00, IEC 96 A Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart