140 A MCS D Safety Contactor

SKU: 100S-D140EZJ22BC
Voltage type for actuating DC
Rated control supply voltage at DC 24 V
Type of electrical connection of main circuit Screw connection
Rated impulse withstand voltage (Uimp) 12
Current (Ie), max 140
Current rating 115
Main current circuit resistance 0.42 mΩ
Rated filament current 140A @ 230/240V, AC-5b
Rated isolation voltage (Ui) 600V per UL, CSA
Auxiliary contacts IP20 IEC 60529/DIN 40050
Rated power (enclosed) 50Hp @ 230V, 3-phase per UL/CSA
Rated operational current for contactor 96A @ 460V, elevator duty (UL/CSA)
Rated power for contactor 75Hp @ 575V, elevator duty (UL/CSA)
Auxiliary contact configuration 2 NO, 2 NC auxiliary bifurcated
Rating of single capacitor 73 kVAR @ 240V @ 50Hz, AC-6b, 40 °C
Rating of group capacitors 79 kVAR @ 1000V @ 50Hz, AC-6b, 60 °C
General purpose current (enclosed) Load carrying capacity: 220 A per UL/CSA
Operating time, closing delay Electronic coil: 35…110 ms @ DC
Power dissipation 24.6 W @ 400V, AC-3, Ie
Short time withstand (Icw) Electronic-EI coil type: 1360A @ 10s, 60 °C
Operating time, opening delay Electronic coil: 25…50 ms @ DC
Coil consumption, hold-in Electronic coil: 6 W @ DC control
Coil consumption, pick-up Electronic coil: 380VA @ 50 Hz, 60 Hz, 50/60 Hz
Total power dissipation DC control (electronic coil): 30.6 W @ 400V, AC-3, Ie
Operating limits, dropout Electronic coil: (0.3…0.5) x Us @ DC control
Switching of lamps Gas discharge lA, open: 225A @ 40°C, AC-5a
Insulation class of the coil Class B per VDE 0660, table 22
Rating for switching AC motors 82/90 kW @ 415V @ 50Hz, 3-phase (AC-2, AC-3)
Switching of hermetically sealed cooling compressor motors 210A @ 690V, AC-8a (manual reset of overload release (50 Hz))
Operating limits, pick-up (0.85…1.1) x Us @ DC control
BS88 fuses current rating Type2 (IEC 60947-4-1): 250A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 350A @ 600V, 10 kA available fault current per UL listed combination
DIN fuses (gG, gL) current rating Type2 (IEC 60947-4-1): 250A @ 690V, 50 kA available fault current
Coil voltage 24V DC electronic coil with electronic interface
Rated operational current (Ie) Electronic-EI coil type: 242A @ 690V, star-delta starting (50 Hz)
UL class J and CSA HRCI-J fuses rating Type2 (IEC60947-4-1): 250A @ 100kA available fault current per UL verified combination
UL inverse-time circuit breaker 200 A @ 600Y/347V @ 30kA available fault current per UL listed combination
Switching of power transformers Apparent power: 87.3 kVA @ 480V @ 60Hz
Rated operational power (Pe) Electronic-EI coil type: 98 kW @ 500V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
Switching of DC loads 3-pole in series: 3.5A @ 440V (shunt-wound motors, starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Optional accessories Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks
Features Mirror contact performance on auxiliary contacts, which are required in ftdback circuit for modern safety applications, The NC auxiliary contacts will not change state when a power contact welds, SUVA third-party certification, AC and DC operating coils,
Contacts 3 main poles with N.C. mechanically linked ftdback contacts
Conventional coil type Yes
Electronic-EI coil type Yes
Screw terminals Thru-hole
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Main contact terminal conductor cross section 8.3 mm @ minimum Ø
Frame terminal block conductor cross section 3…9 mm @ s top
Lifespan Mechanical DC control: 10000000 ops
Switching frequency, max 120 ops/h, AC-4 (approximately 200000 ops)
Recommended torque 88 to 106 in-lb
Weight Non-reverse (Electronic-EI coil type): 3.8 kg @ DC
Conductor cross section Top opening: 16 to 50 mm²
Protection class IP00 IEC 60529/DIN 40050
Altitude of installation site, max 2000 m (NN) per IEC 60947-4
Protection against accidental contact Finger and back-of-hand proof per VDE 0106, part 100
Ambient temperature Storage: -40…80 °C
Single contactor cover IP10 IEC 60529/DIN 40050
Contactor with frame terminal block IP20 IEC 60529/DIN 40050
Peso 4.275 kg
Dimensiones 22.47 × 15.24 × 18.54 cm
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
Installation Instructions 100s-in009_-en-e 100S-IN009
Technical Data 100-td013_-en-p 100-TD013
,
100s-in009_-en-e Installation Instructions
100S-IN009
100-td013_-en-p Technical Data
100-TD013
,

Customers reviews

There are no reviews yet.

Be the first to review “100S-D140EZJ22BC, 140 A MCS D Safety Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart