Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

104-C85D22, IEC 85 A Reversing Contactor

MXN $35,321.00 - (IVA Incluido) + Envío

Sin existencias

IEC 85 A Reversing Contactor

SKU: 104-C85D22

Technical Specifications

Electrical

Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 110 V
Rated control supply voltage at AC 60 Hz 120 V
Current (Ie), max 97 A
Switching frequency, max 120 ops/h
Main current circuit resistance 0.9 mOhm
Cross section per UL/CSA 16 AWG
Rated operational current for contactor at elevator duty (UL/CSA) 68.0 A @ 230V
Rated operational power for contactor at elevator duty (UL/CSA) 60 Hp @ 575V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 60 Hp @ 230V, 60 Hz
Rated filament current 76 A @ 230/240V, AC-5b
Power dissipation 19.5 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm^2 @ 2 conductor
Rated current (enclosed) 80 A @ 115V, 1-phase per UL/CSA
Rated power (enclosed) 7.5 Hp @ 115V, 1-phase per UL/CSA
General purpose current (enclosed) 100 A per UL/CSA
Capacitance, max 940 µF @ short-circuit current of 50 kA
Operating limits, pick-up (0.85…1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Short time withstand (Icw) 700 A for 10 s, 60 °C
Coil consumption, hold-in 4 W @ DC (conventional)
Coil consumption, pick-up 235VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 20…40 ms @ DC (conventional) opening delay
Total power dissipation DC control (conventional): 23.5 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3…0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lamps, open: 90 A @ 40 °C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors 80 A @ 690V, AC-8a (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 3-poles: 7 1/2 Hp @115V (AC-2, AC-3, AC-4), 1-phase (60 Hz)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 160 A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 300 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 250 A @ 600V, 10 kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie) 85 A @ 690V, Star-Delta starting (50 Hz)
Rated operational power (Pe) 90 kW @ 500V, Star-Delta starting (50 Hz)
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 160 A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 150 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 93.7 kVA @ 660V, AC-6a 60 Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 60 kVAR @ 690V, AC-6b 50 Hz, 40 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads 3-Poles in series: 80 A @ 48/60V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Contacts 3 power poles with internal NO or NC auxiliary contact or 4 power poles (9…23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type Yes
Rated coil frequency AC 50/60 Hz, DC

Mechanical

Recommended torque 9 lb.in
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Coil termination Line side connection
Conductor cross section Main contacts, 2 conductor: 2.5…35 mm^2
Lifespan Mechanical DC control: 6000000 ops
Weight 3.22 kg (7.1 lbs) reverse @ DC
Type of electrical connection of main circuit Screw connection

Construction

Options Empty
Optional overload relays Electronic or bimetallic
Optional accessories Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials

Environmental

Auxiliary contacts 1 NO, 1 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55…80 (-67…176)
Protection class auxiliary contact IP2X
Peso 3.386 kg
Dimensiones 30.98 × 18.41 × 21.46 cm
Marcas

Allen-Bradley

Marca

Allen-Bradley

Documentation

RESOURCE PUBLICATION NUMBER
Technical Data 100-TD013

Customers reviews

There are no reviews yet.

Be the first to review “104-C85D22, IEC 85 A Reversing Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart