Voltage type for actuating |
DC |
Rated control supply voltage at AC 50 Hz |
0 V |
Rated control supply voltage at AC 60 Hz |
0 V |
Rated control supply voltage at DC |
24 V |
Current (Ie), max |
9 A |
Switching frequency, max |
250 ops/h |
Main current circuit resistance |
2.7 mOhm |
Cross section per UL/CSA |
16 AWG |
Rated operational current for contactor at elevator duty (UL/CSA) |
7.8 A @ 200V |
Rated isolation voltage (Ui) |
690V @ IEC |
Rated voltage (Ue) |
690V @ AC, 50/60 Hz |
Rated operational power for contactor at wye-delta |
5 Hp @ 230V, 60 Hz |
Rated filament current |
12 A @ 230/240V, AC-5b |
Power dissipation |
0.66 W @ 400V, AC-3, Ie |
Coil terminal conductor cross section |
1…4 mm² @ 2 conductor |
Rated current (enclosed) |
9.8 A @ 115V, 1-phase per UL/CSA |
Rated power (enclosed) |
7.5 Hp @ 575V, 3-phase per UL/CSA |
Coil consumption pick-up (avg/peak) |
14/22 W @ DC (electronic-EA) |
General purpose current (enclosed) |
25 A per UL/CSA |
Capacitance, max |
500 µF @ short-circuit current of 20 kA |
Switching of low inductive loads |
32 A @ 440V, AC-7a per IEC 61095 (50 Hz) |
Operating limits, pick-up |
(0.85…1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of motor load |
9 A @ 400V, AC-7b per IEC 61095 (50 Hz) |
Short time withstand (Icw) |
170 A for 10 s, 60 °C |
Coil consumption, hold-in |
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz |
Coil consumption, pick-up |
75VA @ 50 Hz, 60 Hz, 50/60 Hz |
Operating time |
20…50 ms @ DC (electronic) opening delay |
Total power dissipation |
DC control (electronic): 2.4 W @ 400V, AC-3, Ie |
Operating limits, dropout |
(0.3…0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of lamps |
Gas discharge lamps, open: 22.5 A @ 40 °C, AC-5a |
Switching of hermetically sealed cooling compressor motors |
8 A @ 690V, AC-8a (manual reset of overload release (50 Hz)) |
Coil insulation class |
Class F per IEC 60085, UL Class 105 |
Rating for switching AC motors |
7 1/2 Hp @ 575V, 60 Hz, 3-phase (AC-2, AC-3, AC-4) |
BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 20 A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating |
35 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
UL class CC and CSA HRCI-MISC fuses rating |
20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 |
UL inverse-time circuit breaker |
30 A @ 600Y/347V, 25 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Coil voltage |
24V DC electronic coil |
Rated operational current (Ie) |
9 A @ 415V, AC-4 (50 Hz), ambient temperature 60 °C |
Rated operational power (Pe) |
7.5 kW @ 690V, star-delta starting (50 Hz) |
DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 25 A @ 690V, 50 kA available fault current |
UL class J and CSA HRCI-J fuses rating |
20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Switching of power transformers |
Apparent power: 9.4 kVA @ 500V, AC-6a, 50 Hz (n = 30) |
Switching of 3-phase Capacitors |
Single capacitor: 8 kVAR @ 690V, AC-6b, 50 Hz, 60 °C (inductance of leads between capacitors in parallel: minimum 6 µH) |
Switching of DC loads |
3-pole in series: 6 A @ 220V (shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Contacts |
3 main poles with NC mechanically linked or mirror feedback contacts |
Function |
Reversing contactor |
Rated impulse voltage withstand (Uimp) |
6 kV |
Conventional coil type |
Yes |
Electronic-EI coil type |
Yes |
Rated coil frequency |
AC 50/60 Hz, DC |
Ripple, max |
±15% @ DC (electronic) |
OFF time, min |
50 ms @ DC (electronic) |