Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

140M-D8E-C20, Motor Protection Circuit-Breaker

MXN $14,270.30 - (IVA Incluido) + Envío

Sin existencias

Motor Protection Circuit-Breaker

SKU: 140M-D8E-C20
Adj. Thermal Current Range (A) 14.5 – 20A,MxRtg MCPs(no OvPrt)is 1200.0A
Circuit Breaker Type Mtr Prt Circuit Breaker
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 100 kA
Rated operation power at AC-3, 400 V 10 kw
Rated permanent current Iu 20 A
Rated operation power at AC-3, 230 V 5.5 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 14.5 A
Type of electrical connection of main circuit Screw connection
Rated frequency 60 Hz
Magnetic release current per IEC 260 A
Rated operational current (Ie) per IEC 20 A
Magnetic trip current 260 A
Rated supply current (Ie) 1.6 A
Total power loss (Pv) for circuit breaker at rated load operating temperature 6 W
Current range 14.5 to 20 A
Ultimate short circuit breaking capacity (Icu) per IEC 6kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC 4kA @ 690V
Hp rating, max 7.5Hp @ 230V, 3-phase
Rated insulation voltage (Ui) 690V per IEC, SEV, VDE0660
Electrical life cycle 100000 ops (Ie maximum)
Switching of standard motors per IEC 5.5 kW @ 230/240V (AC-3), 3-phase
KW rating, max 17 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 230/240V
Short circuit current (Type 2 coordination), max 65kA @ 480V
Short circuit current for group motor installation with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max 65kA @ 480V, UL 508-manual motor controller
Rated thermal current (Ith) 1.6…32 A @ up to 60 °C ambient temperature
Short circuit current for combination motor controller with 100-C contactor, max 65 kA @ 480Y/277V per UL 508-self-protected (Type E)
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 65 kA @ 480Y/277V, UL 508-Type F
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp) Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max 65kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 508-manual motor controller
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Overload trip class 10
Phase loss protection Differential release
Degree of protection (IP) IP2X
Weight 373 lb
Mechanical life operations 100000 /h
Breaking capacity High breaking capacity
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Vibration resistance Ops (60068-2-6): 5 G
Shock resistance Transport (60068-2-27): 30 g, 11 ms, all axes
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -20 °C
Site altitude 2000 m (NN)
Dependence on temperature No current reduction
Magnetic release current (±20 %) Fixed setting 13…14 x Ie max. Ie max. = maximum values of setting ranges
Pollution degree 3
Moisture heat (60068-2-3) 40 °C, relative humidity 93 %, 56 d
Dry heat (60086-2-2) 100 °C, relative humidity < 50 %, 7 d
Moisture change climate (600068-2-30) 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame size Frame size D, 32 A
Contactor size for combination motor controller, min 100-C30, UL-508-type E self-protected
Contactor size, min 100-C30 @ 600V
Device construction Built-in device fixed built-in technique
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
Peso 0.404 kg
Dimensiones 9.4 × 5.11 × 9.6 cm
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
Technical Data 140m-td002_-en-p 140M-TD002
,
140m-td002_-en-p Technical Data
140M-TD002
,

Customers reviews

There are no reviews yet.

Be the first to review “140M-D8E-C20, Motor Protection Circuit-Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart