Baud rates |
500 kbps |
Overload selection current range |
3.2 A |
Communication |
DeviceNet |
Short circuit protection |
20 A rated device |
DeviceNet input current surge |
15 A for 250 µs |
DeviceNet input current |
364mA @ 11V DC – 4.0 W |
Total with maximum sensor inputs (4) |
367mA @ 24V DC – 8.8 W |
Overvoltage category |
Control circuit: III per IEC |
Rated operational current |
Power circuit: 16 A maximum |
Product type |
Full voltage starter |
Rated impulse voltage |
Power circuit: 6 kV |
DeviceNet supply voltage rating |
24V DC nominal |
Control (pick up) |
Power requirements: 0.71 A without HOA |
Control (hold in) |
Power requirements: 0.063 A without HOA |
Rated input operation voltage |
24V DC |
Input OFF-state current |
<1.5 mA |
Input OFF-state voltage |
0…5V DC |
Input ON-state voltage |
10…26V DC |
Distance, max |
500 m (1630 ft) @ 125 kbps |
Operating frequency |
Power circuit: 50/60 Hz |
Input ON-state current |
7.2mA @ 24V DC |
Option 1 |
Status only keypad |
Number of contacts |
Output rating- sourced from control circuit: 2 |
Voltage status only |
11…25V DC from DeviceNet |
Outputs current (2) 1 A max. each |
External devices powered by control voltage: 2 A without HOA |
Trip rating |
120% of full load current (FLC) setting |
Total control power (pick up) with max outputs |
External devices powered by control voltage: 73 W with HOA |
Total control power (hold in) with max outputs |
External devices powered by control voltage: 58 W with HOA |
Input compatibility |
IEC 1133 Type 1+ per IEC |
Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
Rated output operation voltage |
Sourced from control circuit: 30V DC |
Insulation voltage |
Power circuit: rated 600V |
Dielectric withstand |
Power circuit: 2500V AC per IEC |
Type of contacts |
Output rating- sourced from control circuit: normally open (NO) |
Current available |
50 mA maximum per input, 200 mA total |
Type of control circuit |
Output rating- sourced from control circuit: electromechanical relay |
Conventional thermal current (Ith) |
Output rating- sourced from control circuit: total of both outputs ≤2 A |
Circuit breaker operational current rating, max |
60kA @ 480V (with gland type: RR) |
RMS symmetrical amperes |
30 kA @ 480Y/277V (with gland type: RR) |
Rated operation voltage |
Power circuit: 200…575V |
3-phase power/motor cable connection |
Conduit entrance with no motor cable |
Input filter – software selectable |
Settable from 0…64 ms in 1 ms increments (ON to OFF) |
Kind of current |
Output ratings (sourced from control circuit): AC/DC (not to be used as an AC/DC power supply) |
Fuse operational current rating, max |
60kA @ 480V (with gland type: RR) |
Total control power (pick up) |
Power requirements: 21 W with HOA |
Total control power (hold in) |
Power requirements: 5.6 W with HOA |
Trip class |
Class 10, 15, 20 |
Operational power rating |
Full voltage starters – IP67/Type 4/12: 7.5 kW @ 400V AC @ 50Hz |
Number of digital inputs |
4 |
Number of digital outputs |
2 |
Supporting protocol for DeviceNet |
True |
Application in industrial area permitted |
True |
Mains frequency |
50/60 Hz |
Short circuit protection device performance (SCPD) type |
Type 1 |
Short circuit rating |
30 kA |
Disconnect |
Motor disconnect |
Connection type |
Quick disconnects |
Utilization category |
Power circuit: AC-3 per IEC |
External devices powered by DeviceNet |
50 mA – total 200 mA |
Electrical life cycle |
Output ratings (sourced from control circuit): 100000 ops (1.8K ops/hr) |