Overload selection current range |
1.1 A |
Short circuit protection |
10 A rated device |
DHCP timeout |
Ethernet port: 30 s |
Web server |
Embedded web server |
Overvoltage category |
Control circuit: III per IEC |
Rated operational current |
Power circuit: 5.5 A maximum |
Product type |
Full voltage starter |
Rated impulse voltage |
Power circuit: 6 kV |
IP address |
Ethernet port: DHCP enabled by default |
Ports |
Ethernet port: embedded switch with 2 ports |
Rated input operation voltage |
Sourced from control circuit (A3/A2): 24V DC |
Input OFF-state current |
Sourced from control circuit (A3/A2): <1.5 mA |
Input OFF-state voltage |
Sourced from control circuit (A3/A2): 0…5V DC |
Module inrush current |
EtherNet/IP version: 1.09 A (A1/A2 with HOA) |
Module steady current |
EtherNet/IP version: 0.3 A (A3/A2 without HOA) |
Total control power (running) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA) |
Input ON-state voltage |
Sourced from control circuit (A3/A2): 10…26V DC |
Operating frequency |
Power circuit: 50/60 Hz |
Input ON-state current |
Sourced from control circuit (A3/A2): 7.2mA @ 24V DC |
Ethernet receptacles |
Ethernet port: 2 D-coded, 4-pin female M12 connectors |
Option 1 |
HAND-OFF-AUTO selector keypad |
Number of contacts |
Output ratings – sourced from control circuit (A1/A2): 2 |
Voltage status only |
Sensor source: 11…26.4V DC from unswitched power (A3-A2) |
Trip rating |
120% of full load current (FLC) setting |
Type of current |
Output ratings – sourced from control circuit (A1/A2): 24 DC |
Input compatibility |
Sourced from control circuit (A3/A2): IEC 1133 Type 1+ per IEC |
Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
Rated output operation voltage |
Output ratings – sourced from control circuit (A1/A2): 26.4V DC |
Insulation voltage |
Power circuit: rated 600V |
Communication rate |
Ethernet port: 10/100 Mbs with auto negotiate half duplex and full duplex |
Dielectric withstand |
Power circuit: 2500V AC per IEC |
Type of contacts |
Output ratings – sourced from control circuit (A1/A2): normally open (N.O.) |
Current available |
Sensor source: 50 mA maximum per input, 200 mA for any single point |
Type of control circuit |
Output ratings – sourced from control circuit (A1/A2): solid state sourcing output |
Conventional thermal current (Ith) |
Output ratings – sourced from control circuit (A1/A2): 0.5 A each, 1 A maximum combined |
Rated operation voltage |
Power circuit: 200…575V |
3-phase power/motor cable connection |
Conduit entrance with motor cable |
Input filter – software selectable |
Sourced from control circuit (A3/A2): settable from 0…64 ms in 1 ms increments (ON to OFF) |
Fuse operational current rating, max |
Time delay: 20 A @ 480Y/277V (with gland type: RR) |
Total control power (pick up) |
EtherNet/IP version: 7.2 W (A3/A2 without HOA) |
Peak output current |
Output ratings – sourced from control circuit (A1/A2): current limited 2-8 A (5 A nominal) @ 24V DC |
Trip class |
Class 10, 15, 20 |
Operational power rating |
Full voltage starters – IP67/NEMA Type 4: 3Hp @ 460V AC, 60 Hz |
Data |
Ethernet port: transported over both TCP and UDP, minimum of 500 I/O packets/s (pps), supports up to 150 concurrent TCP sockets |
Input frequency response, max |
Sourced from control circuit (A3/A2): 200 Hz (DeviceLogix response is greater than 200 Hz, network response depends on control system network performance.) |
Device connections |
TCP port supports 5 concurrent incoming connections |
Number of digital inputs |
4 |
Number of digital outputs |
2 |
Application in industrial area permitted |
True |
Supporting protocol for EtherNet/IP |
True |
Mains frequency |
50/60 Hz |
Short circuit protection device performance (SCPD) type |
Type 1 |
Short circuit rating |
30 kA |
Disconnect |
Motor disconnect |
Conection type |
Quick disconnects |
Utilization category |
Power circuit: AC-3 per IEC |
Security |
Web server: login and password configurable |
Configuration |
Web server: status, diagnostics and configuration tabs |
E-mail |
Web server: support simple mail transfer protocol (SMTP) |
Off-state leakage current, max |
Output ratings – sourced from control circuit (A1/A2): 10 µA |
Blocking voltage, max |
Output ratings – sourced from control circuit (A1/A2): 35V DC |
On-state voltage @ max. output |
Output ratings – sourced from control circuit (A1/A2): 1.5V DC |
Fault recovery |
DLR: Ring recovery time is less than 3 ms for a 50 node network |
Device level ring |
Beacon-based performance including IEEE 1588 end to end transparent clock |
Load types |
Output ratings – sourced from control circuit (A1/A2): resistive or light inductive |
Surge suppression |
Output ratings – sourced from control circuit (A1/A2): integrated diode, clA @ 35V DC |
Cycle rate, max |
Output ratings – sourced from control circuit (A1/A2): 30 ops/minute capacitive and inductive loads |
Thermo-protection |
Output ratings – sourced from control circuit (A1/A2): integrated short circuit and over current protection |