Communication |
DeviceNet |
Short circuit protection |
25 A rated device |
DeviceNet input current surge |
15 A for 250 µs |
DeviceNet input current |
364mA @ 11V DC – 4.0 W |
Total w/max. sensor inputs (4) |
367mA @ 24V DC – 8.8 W |
Overvoltage category |
Control circuit: III per IEC |
Product type |
AC Drive |
Rated impulse voltage |
Power circuit: rated 6 kV |
DeviceNet supply voltage rating |
Range 11…25V DC @ 24V DC nominal |
Baud rates |
125, 250, 500 kbps |
Input OFF-state current |
<1.5 mA |
Rated output operating current, max |
Power circuit: 6 A @ 3-phase, 3 Hp rating |
Input OFF-state voltage |
0…5V DC |
Hp (KW) rating/input voltage, max |
Sensorless vector control: 5 Hp (3.3 kW)/480V AC |
Input ON-state voltage |
10…26V DC |
Torque performance mode |
Sensorless vector control and volts per Hz |
Distance, max |
500 m (1630 ft) @ 125 kbps |
Operating frequency |
Power circuit: 50/60 Hz |
Input ON-state current |
7.2mA @ 24V DC |
Option 1 |
HAND-OFF-AUTO selector keypad with jog function |
Number of contacts |
Output rating- sourced from control circuit: 2 |
Short-circuit protection device list |
Size per NEC group motor per UL/NEMA |
Input compatibility |
IEC 1133 Type 1+ |
Application in industrial area permitted (SCPD list) |
Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
Rated output operation voltage |
Sourced from control circuit: 240V AC / 30V DC |
Drive output current ratings |
6.0A @ 460V, 3 Hp, 3-phase, 60 Hz |
Drive input current ratings |
9.00A @ 380V, 2.2 kW, 3-phase, 50 Hz |
Insulation voltage |
Power circuit: rated 600V AC |
Frequency accuracy – digital input |
Sensorless vector control: within ±0.05% of set output frequency. |
Carrier frequency |
Sensorless vector control: 2…16 kHz. drive rating is based on 4 kHz. |
Speed regulation – open loop with slip compensation |
Sensorless vector control: ±1% of base speed across a 60:1 speed range |
DB resistance, min |
97 Ω @ drive input voltage of 480V @ 50/60Hz, 3-phase, 2.2 kW, 3 Hp |
Dielectric withstand |
Power circuit: 2500V AC per IEC |
Type of contacts |
Output rating- sourced from control circuit: normally open (NO) |
Electronic motor overload protection |
Sensorless vector control: class 10 protection with speed sensitive response |
Outputs current (2) 1 A each, max |
External devices powered by control voltage: 2 A @ with brake and output contactor |
Current available |
Sensor source: 50 mA maximum per input, 200 mA total |
Type of control circuit |
Output rating- sourced from control circuit: electromechanical relay |
Conventional thermal current (Ith) |
Output rating- sourced from control circuit: total of both outputs ≤2 A |
RMS symmetrical amperes |
30 kA @ 600Y/347V per IEC |
Rated operation voltage |
Power circuit: 380Y/220…480Y/277V AC |
3-phase power/motor cable connection |
Conduit entrance with motor cable |
Input filter – software selectable |
ON to OFF: settable from 0…64 ms in 1 ms increments |
Kind of current |
Output rating- sourced from control circuit: AC/DC |
Nominal control power (pick up) |
External devices powered by control voltage: 300VA @ with maximum outputs, with brake and output contactor |
Nominal control power (hold in) |
External devices powered by control voltage: 278VA @ with maximum outputs, brake or output contactor |
Trip class |
Class 10 |
Stop modes |
Sensorless vector control: multiple progmable stop modes including – rA, coast, DC-brake, rA-to-hold and S curve. |
Number of digital inputs |
4 |
Number of digital outputs |
2 |
Supporting protocol for DeviceNet |
True |
Application in industrial area permitted |
True |
Max. output frequency |
400 Hz |
Mains frequency |
50/60 Hz |
Drive efficiency |
97.5% Typical |
Disconnect |
Motor disconnect |
Connection type |
Quick disconnects |
Drive output frequency |
0…400 Hz Progmable |
Utilization category |
Power circuit: AC-3 per IEC |
Preset speeds |
Sensorless vector control: 8 |
Skip frequency |
Sensorless vector control: Yes |
StepLogic® functionality |
Sensorless vector control: Yes |
Timer/counter functions |
Sensorless vector control: Yes |
External devices powered by DeviceNet |
50 mA – total 200 mA |
Voltage status |
Sensor source: 11…25V DC from DeviceNet |
Overload protection |
I²t overload protection – 150% @ 60s, 200% @ 30s |
Internal fan |
Fan L10 ops data: 80K hours at 40 °C and 98K hours at 25 °C (77 °F) ambient |
Accel/decel |
Sensorless vector control: two independently progmable accel and decel times. Each time may be progmed from 0…600 s in 0.1 s increments. |
There are no reviews yet.