Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

ATV340U55N4E variable speed drive, Altivar Machine ATV340, 5.5kW, heavy duty, 400V, 3 phases, Ethernet

MXN $125,279.00 - (IVA Incluido) + Envío

5 disponibles

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 5.5kW / 7.5hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 2.9kg and its dimensions are, 110mm wide, 270mm high, 234mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Comprar Ahora
SKU: ATV340U55N4E

variable speed drive, Altivar Machine ATV340, 5.5kW, heavy duty, 400V, 3 phases, Ethernet

ATV340U55N4E

Main
Range of Product Altivar Machine ATV340
Product or Component Type Variable speed drive
Product Specific Application Machine
variant Standard version
Mounting Mode Cabinet mount
Communication Port Protocol EtherNet/IP
Modbus TCP
Modbus serial
Phase 3 phase
Supply frequency 50…60 Hz +/- 5 %
[Us] rated supply voltage 380…480 V – 15…10 %
Nominal output current 12.7 A
Motor power kW 7.5 kW normal duty
5.5 kW heavy duty
Maximum Horse Power Rating 10 hp normal duty
7 hp heavy duty
EMC filter Class C3 EMC filter integrated
IP degree of protection IP20
Complementary
Discrete input number 5
Discrete input type PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V)
DI1…DI5 safe torque off, 24 V DC 30 V)3.5 kOhm
programmable
number of preset speeds 16 preset speeds
Discrete output number 2.0
Discrete output type Programmable output DQ1, DQ2 30 V DC 100 mA
Analogue input number 2
Analogue input type AI1 software-configurable current 0…20 mA 250 Ohm 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage 0…10 V DC 31.5 kOhm 12 bits
AI2 software-configurable voltage – 10…10 V DC 31.5 kOhm 12 bits
Analogue output number 1
Analogue output type Software-configurable voltage AQ1 0…10 V DC 470 Ohm 10 bits
Software-configurable current AQ1 0…20 mA 500 Ohm 10 bits
Relay output number 2
Output voltage <= power supply voltage
Relay output type Relay outputs R1A
Relay outputs R1C 100000 cycles
Relay outputs R2A
Relay outputs R2C 100000 cycles
Maximum switching current Relay output R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2C resistive, cos phi = 1 5 A 30 V DC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1B 5 mA 24 V DC
Relay output R2C 5 mA 24 V DC
Physical interface 2-wire RS 485
Connector Type 3 RJ45
Method of access Slave Modbus RTU
Slave Modbus TCP
Transmission Rate 4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Optimized torque mode
Constant torque standard
Variable torque standard
Synchronous motor control profile Reluctance motor
Permanent magnet motor
Pollution degree 2 IEC 61800-5-1
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear adjustable separately from 0.01…9999 s
S, U or customized
Motor slip compensation Automatic whatever the load
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Switching frequency 2…16 kHz adjustable
7…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 15.3 A 380 V normal duty)
12.2 A 480 V normal duty)
20.0 A 380 V heavy duty)
16.0 A 480 V heavy duty)
Line current 20 A 380 V without line choke heavy duty)
16 A 480 V without line choke heavy duty)
15.3 A 380 V with external line choke normal duty)
12.2 A 480 V with external line choke normal duty)
11.6 A 380 V with external line choke heavy duty)
9.4 A 480 V with external line choke heavy duty)
Maximum Input Current per Phase 20.0 A
Maximum output voltage 480 V
Apparent power 12.1 kVA 480 V normal duty)
13.3 kVA 480 V heavy duty)
Maximum transient current 18.2 A 60 s normal duty)
19.1 A 60 s heavy duty)
22.3 A 2 s normal duty)
22.9 A 2 s heavy duty)
Electrical connection Screw terminal 4…6 mm² DC bus
Screw terminal 0.2…2.5 mm² control
Screw terminal 1.5…6 mm² line side
Screw terminal 1.5…6 mm² motor
Prospective line Isc 22 kA
Base load current at high overload 12.7 A
Base load current at low overload 16.5 A
Power dissipation in W Natural convection 134 W 380 V 4 kHz heavy duty)
Forced convection 134 W 380 V 4 kHz heavy duty)
Natural convection 164 W 380 V 4 kHz normal duty)
Forced convection 164 W 380 V 4 kHz normal duty)
Electrical connection DC bus screw terminal 4…6 mm² AWG 12…AWG 10
Control screw terminal 0.2…2.5 mm² AWG 24…AWG 12
Line side screw terminal 1.5…6 mm² AWG 14…AWG 10
Motor screw terminal 1.5…6 mm² AWG 14…AWG 10
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type External thermal protection motor
Safe torque off motor
Motor phase loss motor
External thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent drive
Output overcurrent between motor phase and earth drive
Output overcurrent between motor phases drive
Short-circuit between motor phase and earth drive
Short-circuit between motor phases drive
Motor phase loss drive
DC Bus overvoltage drive
Line supply overvoltage drive
Line supply undervoltage drive
Input supply loss drive
Exceeding limit speed drive
Break on the control circuit drive
Width 4.33 in (110.0 mm)
Height 10.63 in (270.0 mm)
Depth 9.21 in (234.0 mm)
Net Weight 6.39 lb(US) (2.9 kg)
Continuous output current 16.5 A 4 kHz normal duty
12.7 A 4 kHz heavy duty
Environment
Operating altitude <= 9842.52 ft (3000 m) with current derating above 1000m
Operating position Vertical +/- 10 degree
Product Certifications UL
CSA
TÜV
EAC
CTick
marking CE
Standards IEC 61800-3
IEC 61800-5-1
IEC 60721-3
IEC 61508
IEC 13849-1
UL 618000-5-1
UL 508C
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 70 m/s² at 22 ms
Maximum acceleration under vibrational stress (during operation) 5 m/s² at 9…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…9 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 20077.44 Gal/hr(US) (76.0 m3/h)
Type of cooling Forced convection
Overvoltage category Class III
Regulation loop Adjustable PID regulator
Noise level 46.6 dB
Pollution degree 2
Ambient air transport temperature -40…158 °F (-40…70 °C)
Ambient air temperature for operation 5…122 °F (-15…50 °C) without derating vertical position)
122…140 °F (50…60 °C) with derating factor vertical position)
Ambient Air Temperature for Storage -40…158 °F (-40…70 °C)
Isolation Between power and control terminals
Ordering and shipping details
Category US1CP4B22182
Discount Schedule CP4B
GTIN 3606480967030
Returnability Yes
Country of origin US
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.20 in (13.200 cm)
Package 1 Width 14.57 in (37.000 cm)
Package 1 Length 12.60 in (32.000 cm)
Package 1 Weight 8.40 lb(US) (3.810 kg)
Unit Type of Package 2 S06
Number of Units in Package 2 10
Package 2 Height 29.53 in (75.000 cm)
Package 2 Width 23.62 in (60.000 cm)
Package 2 Length 31.50 in (80.000 cm)
Package 2 Weight 112.22 lb(US) (50.900 kg)
Peso 3.79 kg
Dimensiones 37 × 32 × 13.2 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
User guide
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “ATV340U55N4E variable speed drive, Altivar Machine ATV340, 5.5kW, heavy duty, 400V, 3 phases, Ethernet”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart