contactor TeSys Deca – 3 poles – AC-3 440V 50 A – coil 440V AC
LC1D50R7
Range | TeSys |
---|---|
Range of Product | TeSys Deca |
Product or Component Type | Contactor |
Device short name | LC1D |
contactor application | Resistive load Motor control |
Utilisation category | AC-3 AC-1 AC-4 AC-2 |
poles description | 3P |
[Ue] rated operational voltage | Power circuit <= 690 V AC 25…400 Hz |
[Ie] rated operational current | 50 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 440 V AC 50/60 Hz |
Motor power kW | 22 kW at 380…400 V AC 50 Hz (AC-3) 25 kW at 415 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3) 30 kW at 500 V AC 50 Hz (AC-3) 33 kW at 660…690 V AC 50 Hz (AC-3) 15 kW at 220…230 V AC 50 Hz (AC-3) 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 1000 V AC 50 Hz (AC-3) |
---|---|
Maximum Horse Power Rating | 3 hp at 115 V AC 60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors 15 hp at 200/208 V AC 60 Hz for 3 phase motors 15 hp at 230/240 V AC 60 Hz for 3 phase motors 40 hp at 460/480 V AC 60 Hz for 3 phase motors 40 hp at 575/600 V AC 60 Hz for 3 phase motors |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 10 A (at 140.0000000000 °F (60 °C)) for control circuit 80 A (at 140.0000000000 °F (60 °C)) for power circuit |
Irms rated making capacity | 900 A at 440 V for power circuit conforming to IEC 60947 140 A AC for control circuit conforming to IEC 60947-5-1 |
Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit |
Power dissipation per pole | 3.7 W AC-3 9.6 W AC-1 |
[Ui] rated insulation voltage | Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-1 Power circuit 690 V IEC 60947-1 |
Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 6000000 cycles |
Control circuit type | AC 50/60 Hz |
Coil technology | Without built-in bidirectional peak limiting diode suppressor |
Control circuit voltage limits | 0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz 0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz 1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz |
Inrush power in VA | 140 VA cos phi 0.75 (at 68.0000000000 °F (20 °C)) 160 VA cos phi 0.75 (at 68.0000000000 °F (20 °C)) |
Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) 15 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) |
Heat dissipation | 4…5 W at 50/60 Hz for control circuit |
Operating time | 4…19 ms opening 12…26 ms closing |
Maximum operating rate | 3600 cyc/h 140.0000000000 °F (60 °C) |
Connections – terminals | Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: rigid Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: rigid Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible without cable end Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: flexible without cable end Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible with cable end Power circuit: screw terminals 2 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end |
Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Terminals description ISO n°1 | (21-22)NC (A1-A2)CO (13-14)NO |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts |
Mounting Support | Plate Rail |
Standards | UL 508 EN 60947-5-1 EN 60947-4-1 IEC 60947-4-1 CSA C22.2 No 14 IEC 60947-5-1 |
---|---|
Product Certifications | UL DNV BV GOST RINA CSA CCC LROS (Lloyds register of shipping) GL |
IP degree of protection | IP2X IEC 60529 IP2X VDE 0106 |
Climatic withstand | IACS E10 exposure to damp heat |
Operating altitude | 0…9842.52 ft (0…3000 m) |
Fire resistance | 1562.0000000000 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Shocks contactor opened 10 Gn for 11 ms) Shocks contactor closed 15 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5…300 Hz) Vibrations contactor closed 4 Gn, 5…300 Hz) |
Height | 5.0000000000 in (127 mm) |
Width | 3.0 in (75 mm) |
Depth | 4.7 in (119 mm) |
Net Weight | 3.09 lb(US) (1.4 kg) |
Category | 22357-CTR,TESYS D,OPEN,40-65A AC |
---|---|
Discount Schedule | I12 |
GTIN | 3389110426175 |
Returnability | No |
Country of origin | CZ |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 3.2 in (8.2 cm) |
Package 1 Width | 4.9 in (12.5 cm) |
Package 1 Length | 5.3 in (13.5 cm) |
Package 1 Weight | 3.192 lb(US) (1.448 kg) |
Warranty | 18 months |
---|
There are no reviews yet.