IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 2 NO and 2 NC, 110VAC 50/60Hz coil, open style
LC1D80008F7
Range | TeSys |
---|---|
Range of Product | TeSys Deca |
Product or Component Type | Contactor |
Device short name | LC1D |
contactor application | Resistive load |
Utilisation category | AC-1 |
poles description | 4P |
[Ue] rated operational voltage | Power circuit <= 690 V AC 25…400 Hz |
[Ie] rated operational current | 125 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 110 V AC 50/60 Hz |
Compatibility code | LC1D |
---|---|
Pole contact composition | 2 NO + 2 NC |
Protective cover | Without |
[Ith] conventional free air thermal current | 125 A (at 140.0000000000 °F (60 °C)) for power circuit |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 104.0000000000 °F (40 °C) – 10 s for power circuit 990 A 104.0000000000 °F (40 °C) – 1 s for power circuit 135 A 104.0000000000 °F (40 °C) – 10 min for power circuit 320 A 104.0000000000 °F (40 °C) – 1 min for power circuit |
Associated fuse rating | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit |
Average impedance | 0.8 mOhm – Ith 125 A 50 Hz for power circuit |
Power dissipation per pole | 12.5 W AC-1 |
[Ui] rated insulation voltage | Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 4 Mcycles |
Electrical durability | 0.8 Mcycles 125 A AC-1 <= 440 V |
Control circuit type | AC 50/60 Hz |
Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.85…1.1 Uc -40.0000000000…131.0000000000 °F (-40…55 °C) operational AC 60 Hz 0.3…0.6 Uc -40.0000000000…131.0000000000 °F (-40…55 °C) drop-out AC 50/60 Hz 0.8…1.1 Uc -40.0000000000…131.0000000000 °F (-40…55 °C) operational AC 50 Hz |
Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C)) 245 VA 50 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C)) |
Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) 26 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) |
Heat dissipation | 6…10 W at 50/60 Hz |
Operating time | 20…35 ms closing 6…20 ms opening |
Maximum operating rate | 3600 cyc/h 140.0000000000 °F (60 °C) |
Connections – terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end |
Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
Mounting Support | Rail Plate |
Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 |
---|---|
Product Certifications | UL CSA CCC EAC UKCA CB EU-RO-MR by DNV-GL |
IP degree of protection | IP20 front face IEC 60529 |
Protective treatment | THIEC 60068-2-30 |
Climatic withstand | IACS E10 exposure to damp heat |
Permissible ambient air temperature around the device | -40.0000000000…140.0000000000 °F (-40…60 °C) 140.0000000000…158.0000000000 °F (60…70 °C) with derating |
Operating altitude | 0…9842.52 ft (0…3000 m) |
Fire resistance | 1562.0000000000 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open 2 Gn, 5…300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5…300 Hz) Shocks contactor closed 10 Gn for 11 ms) |
Height | 5.0000000000 in (127 mm) |
Width | 3.8 in (96 mm) |
Depth | 5.5 in (140 mm) |
Net Weight | 4.06 lb(US) (1.84 kg) |
Category | US10I1222359 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389110075137 |
Returnability | Yes |
Country of origin | FR |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.102 in (15.500 cm) |
Package 1 Width | 4.331 in (11.000 cm) |
Package 1 Length | 5.433 in (13.800 cm) |
Package 1 Weight | 3.933 lb(US) (1.784 kg) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 5 |
Package 2 Height | 5.906 in (15.000 cm) |
Package 2 Width | 11.811 in (30.000 cm) |
Package 2 Length | 15.748 in (40.000 cm) |
Package 2 Weight | 21.308 lb(US) (9.665 kg) |
Warranty | 18 months |
---|