Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

LC1D95M7, IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style

MXN $11,655.00 - (IVA Incluido) + Envío

71 disponibles

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Comprar Ahora
SKU: LC1D95M7

IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style

LC1D95M7

Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit
125 A (at <140 °F (60 °C)) at <= 690 V AC-1 for power circuit
95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Motor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
25 kW at 220…230 V AC 50 Hz (AC-3e)
45 kW at 380…400 V AC 50 Hz (AC-3e)
45 kW at 415…440 V AC 50 Hz (AC-3e)
55 kW at 500 V AC 50 Hz (AC-3e)
45 kW at 660…690 V AC 50 Hz (AC-3e)
Maximum Horse Power Rating 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phase motors
30 hp at 230/240 V AC 60 Hz for 3 phase motors
60 hp at 460/480 V AC 60 Hz for 3 phase motors
60 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 104 °F (40 °C) – 1 s for power circuit
800 A 104 °F (40 °C) – 10 s for power circuit
400 A 104 °F (40 °C) – 1 min for power circuit
135 A 104 °F (40 °C) – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8…1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz
0.85…1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz
0.3…0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
1…1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20…35 ms closing
6…20 ms opening
Maximum operating rate 3600 cyc/h 140 °F (60 °C)
Connections – terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Rail
Plate
Environment
Standards EN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product Certifications IECEE CB Scheme
UL
CSA
CCC
EAC
LROS (Lloyds register of shipping)
RINA
BV
DNV-GL
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5…300 Hz)
Shocks contactor open 8 Gn for 11 ms)
Vibrations contactor closed 3 Gn, 5…300 Hz)
Shocks contactor closed 10 Gn for 11 ms)
Height 5.0000000000 in (127 mm)
Width 3.3 in (85 mm)
Depth 5.1 in (130 mm)
Net Weight 3.55 lb(US) (1.61 kg)
Ordering and shipping details
Category US10I1222359
Discount Schedule 0I12
GTIN 3389110451634
Returnability Yes
Country of origin CZ
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.512 in (14.000 cm)
Package 1 Width 5.315 in (13.500 cm)
Package 1 Length 3.740 in (9.500 cm)
Package 1 Weight 3.430 lb(US) (1.556 kg)
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 17.835 lb(US) (8.090 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 29.528 in (75.000 cm)
Package 3 Width 23.622 in (60.000 cm)
Package 3 Length 31.496 in (80.000 cm)
Package 3 Weight 309.221 lb(US) (140.260 kg)
Contractual warranty
Warranty 18 months
Peso 1.556 kg
Dimensiones 13.5 × 14 × 9.5 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC1D95M7, IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart