Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 110VAC coil
LC1K09008F7
Range | TeSys |
---|---|
Product or Component Type | Contactor |
Device short name | LC1K |
Device Application | Control |
contactor application | Resistive load |
Utilisation category | AC-1 |
---|---|
poles description | 4P |
power pole contact composition | 2 NO + 2 NC |
[Ue] rated operational voltage | Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz |
[Ie] rated operational current | 20 A (at <140.0000000000 °F (60 °C)) at <= 690 V AC AC-1 for power circuit |
Control circuit type | AC 50/60 Hz |
[Uc] control circuit voltage | 110 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
Overvoltage category | III |
[Ith] conventional free air thermal current | 20 A (at 140.0000000000 °F (60 °C)) for power circuit 10 A (at 122.0000000000 °F (50 °C)) for signalling circuit |
Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947 |
Rated breaking capacity | 110 A at 220…230 V conforming to IEC 60947 110 A at 380…400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660…690 V conforming to IEC 60947 |
[Icw] rated short-time withstand current | 90 A 122.0000000000 °F (50 °C) – 1 s for power circuit 85 A 122.0000000000 °F (50 °C) – 5 s for power circuit 80 A 122.0000000000 °F (50 °C) – 10 s for power circuit 60 A 122.0000000000 °F (50 °C) – 30 s for power circuit 45 A 122.0000000000 °F (50 °C) – 1 min for power circuit 40 A 122.0000000000 °F (50 °C) – 3 min for power circuit 20 A 122.0000000000 °F (50 °C) – >= 15 min for power circuit |
Associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit |
Average impedance | 3 mOhm – Ith 20 A 50 Hz for power circuit |
[Ui] rated insulation voltage | Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14 |
Inrush power in VA | 30 VA (at 68.0000000000 °F (20 °C)) |
Hold-in power consumption in VA | 4.5 VA (at 68.0000000000 °F (20 °C)) |
Heat dissipation | 1.3 W |
Control circuit voltage limits | Operational: 0.8…1.15 Uc (at <122.0000000000 °F (50 °C)) Drop-out: >= 0.20 Uc (at <122.0000000000 °F (50 °C)) |
Connections – terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end |
Maximum operating rate | 3600 cyc/h |
Signalling circuit frequency | <= 400 Hz |
Mounting Support | Rail Plate |
Tightening torque | 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 |
Operating time | 10…20 ms coil de-energisation and NO opening 10…20 ms coil energisation and NO closing 15…25 ms coil de-energisation and NC closing 5…15 ms coil energisation and NC opening |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 10 Mcycles |
Electrical durability | 0.16 Mcycles 20 A AC-1 <= 690 V |
Mechanical robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5…300 Hz IEC 60068-2-6 |
Height | 2.3 in (58 mm) |
Width | 1.8 in (45 mm) |
Depth | 2.2 in (57 mm) |
Net Weight | 0.40 lb(US) (0.18 kg) |
Standards | EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 |
---|---|
Product Certifications | CB Scheme CCC UL CSA EAC CE UKCA |
IP degree of protection | IP2X VDE 0106 |
Protective treatment | TC IEC 60068 TC DIN 50016 |
Ambient Air Temperature for Storage | -58.0000000000…176.0000000000 °F (-50…80 °C) |
Operating altitude | 6561.68 ft (2000 m) without derating |
Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Category | US10I1222326 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389110488845 |
Returnability | Yes |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 1.9 in (4.9 cm) |
Package 1 Width | 2.4 in (6.1 cm) |
Package 1 Length | 2.6 in (6.5 cm) |
Package 1 Weight | 6.4 oz (181.0 g) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 50 |
Package 2 Height | 5.9 in (15.0 cm) |
Package 2 Width | 11.8 in (30.0 cm) |
Package 2 Length | 15.7 in (40.0 cm) |
Package 2 Weight | 20.655 lb(US) (9.369 kg) |
Warranty | 18 months |
---|