TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 110V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

SKU: LC1K09008F7

Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 110VAC coil

LC1K09008F7

Main
Range TeSys
Product or Component Type Contactor
Device short name LC1K
Device Application Control
contactor application Resistive load
Complementary
Utilisation category AC-1
poles description 4P
power pole contact composition 2 NO + 2 NC
[Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz
Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current 20 A (at <140.0000000000 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140.0000000000 °F (60 °C)) for power circuit
10 A (at 122.0000000000 °F (50 °C)) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 122.0000000000 °F (50 °C) – 1 s for power circuit
85 A 122.0000000000 °F (50 °C) – 5 s for power circuit
80 A 122.0000000000 °F (50 °C) – 10 s for power circuit
60 A 122.0000000000 °F (50 °C) – 30 s for power circuit
45 A 122.0000000000 °F (50 °C) – 1 min for power circuit
40 A 122.0000000000 °F (50 °C) – 3 min for power circuit
20 A 122.0000000000 °F (50 °C) – >= 15 min for power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA C22.2 No 14
Inrush power in VA 30 VA (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 4.5 VA (at 68.0000000000 °F (20 °C))
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <122.0000000000 °F (50 °C))
Drop-out: >= 0.20 Uc (at <122.0000000000 °F (50 °C))
Connections – terminals screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate 3600 cyc/h
Signalling circuit frequency <= 400 Hz
Mounting Support Rail
Plate
Tightening torque 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
Operating time 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
15…25 ms coil de-energisation and NC closing
5…15 ms coil energisation and NC opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 10 Mcycles
Electrical durability 0.16 Mcycles 20 A AC-1 <= 690 V
Mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6
Vibrations contactor opened2 Gn, 5…300 Hz IEC 60068-2-6
Height 2.3 in (58 mm)
Width 1.8 in (45 mm)
Depth 2.2 in (57 mm)
Net Weight 0.40 lb(US) (0.18 kg)
Environment
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product Certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X VDE 0106
Protective treatment TC IEC 60068
TC DIN 50016
Ambient Air Temperature for Storage -58.0000000000…176.0000000000 °F (-50…80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Ordering and shipping details
Category US10I1222326
Discount Schedule 0I12
GTIN 3389110488845
Returnability Yes
Country of origin ID
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.9 in (4.9 cm)
Package 1 Width 2.4 in (6.1 cm)
Package 1 Length 2.6 in (6.5 cm)
Package 1 Weight 6.4 oz (181.0 g)
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 5.9 in (15.0 cm)
Package 2 Width 11.8 in (30.0 cm)
Package 2 Length 15.7 in (40.0 cm)
Package 2 Weight 20.655 lb(US) (9.369 kg)
Contractual warranty
Warranty 18 months
Peso 0.181 kg
Dimensiones 6.1 × 6.5 × 4.9 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC1K09008F7, Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 110VAC coil”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart