TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 110 V AC coil
LC2D09F7
Range | TeSys TeSys Deca |
---|---|
Product name | TeSys D TeSys Deca |
Product or Component Type | Reversing contactor |
Device short name | LC2D |
contactor application | Resistive load Motor control |
Utilisation category | AC-1 AC-3 AC-3e |
device presentation | Preassembled with reversing power busbar |
poles description | 3P |
power pole contact composition | 3 NO |
[Ue] rated operational voltage | Power circuit <= 690 V AC 25…400 Hz Power circuit <= 300 V DC |
[Ie] rated operational current | 9 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 25 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
Motor power kW | 2.2 kW at 220…230 V AC 50-60 Hz 4 kW at 380…400 V AC 50-60 Hz 4 kW at 415 V AC 50-60 Hz 4 kW at 440 V AC 50-60 Hz 5.5 kW at 500 V AC 50-60 Hz 5.5 kW at 660…690 V AC 50-60 Hz |
motor power HP (UL / CSA) | 0.5 hp at 115 V AC 60 Hz for 1 phase motors 1 hp at 230/240 V AC 60 Hz for 1 phase motors 2 hp at 200/208 V AC 60 Hz for 3 phase motors 2 hp at 230/240 V AC 60 Hz for 3 phase motors 5 hp at 460/480 V AC 60 Hz for 3 phase motors 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors |
Control circuit type | AC 50/60 Hz |
[Uc] control circuit voltage | 110 V AC 50/60 Hz |
Auxiliary contact composition | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
Overvoltage category | III |
[Ith] conventional free air thermal current | 10 A (at 140.0000000000 °F (60 °C)) for signalling circuit 25 A (at 140.0000000000 °F (60 °C)) for power circuit |
Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 30 A 104.0000000000 °F (40 °C) – 10 min for power circuit 61 A 104.0000000000 °F (40 °C) – 1 min for power circuit 105 A 104.0000000000 °F (40 °C) – 10 s for power circuit 210 A 104.0000000000 °F (40 °C) – 1 s for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
Associated fuse rating | 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
Average impedance | 2.5 mOhm – Ith 25 A 50 Hz for power circuit |
[Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
Electrical durability | 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V |
Power dissipation per pole | 0.2 W AC-3 1.56 W AC-1 0.2 W AC-3e |
Front cover | With |
Interlocking type | Mechanical |
Mounting Support | Rail Plate |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
Product Certifications | DNV CSA CCC UL GL LROS (Lloyds register of shipping) BV RINA GOST UKCA |
Connections – terminals | Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Power circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid |
Tightening torque | Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2 |
Operating time | 12…22 ms closing 4…19 ms opening |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 15 Mcycles |
Maximum operating rate | 3600 cyc/h 140.0000000000 °F (60 °C) |
Coil technology | Without built-in suppressor module |
---|---|
Control circuit voltage limits | 0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz 0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz 1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz |
Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C)) 70 VA 50 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C)) |
Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) 7 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) |
Heat dissipation | 2…3 W 50/60 Hz |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Signalling circuit frequency | 25…400 Hz |
Minimum switching current | 5 mA for signalling circuit |
Minimum switching voltage | 17 V for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face IEC 60529 |
---|---|
Climatic withstand | IACS E10 IEC 60947-1 Annex Q category D |
Protective treatment | TH IEC 60068-2-30 |
Pollution degree | 3 |
Ambient air temperature for operation | -40.0000000000…140.0000000000 °F (-40…60 °C) 140.0000000000…158.0000000000 °F (60…70 °C) with derating |
Ambient Air Temperature for Storage | -76.0000000000…176.0000000000 °F (-60…80 °C) |
Operating altitude | 0…9842.52 ft (0…3000 m) |
Fire resistance | 1562.0000000000 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open2 Gn, 5…300 Hz Vibrations contactor closed4 Gn, 5…300 Hz Shocks contactor open10 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms |
Height | 3.03 in (77 mm) |
Width | 3.5 in (90 mm) |
Depth | 3.4 in (86 mm) |
Net Weight | 1.515 lb(US) (0.687 kg) |
Category | US10I1222354 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389110383386 |
Returnability | Yes |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.449 in (11.300 cm) |
Package 1 Width | 3.740 in (9.500 cm) |
Package 1 Length | 5.315 in (13.500 cm) |
Package 1 Weight | 28.571 oz (810.000 g) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 6 |
Package 2 Height | 5.906 in (15.000 cm) |
Package 2 Width | 11.811 in (30.000 cm) |
Package 2 Length | 15.748 in (40.000 cm) |
Package 2 Weight | 11.471 lb(US) (5.203 kg) |
Warranty | 18 months |
---|
There are no reviews yet.