TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. TeSys T has a number of components that increase the flexibility of the system. This expansion module adds functionalities to the TeSys T controller. It adds voltage mesurement between phases up to 690 V nominal and 4 additional inputs. Module has 4 discrete logic inputs. 120 to 240 VAC is used to power the module. Module has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Comprar Ahora
SKU: LTMEV40FM

Extension module, TeSys T, 4 inputs, 100 to 240VAC, for LTMR controller

LTMEV40FM

Main
Range TeSys
Product name TeSys T
Device short name LTME
Product or Component Type Extension module
Device Application Equipment monitoring and control
Range compatibility TeSys TeSys T LTMR motor controller
Supply Via the controller
Complementary
[Ui] rated insulation voltage 690 V EN/IEC 60947-1
690 V CSA C22.2 No 14
690 V UL 508
[Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs EN/IEC 60947-4-1
6 kV current or voltage measurement circuit EN/IEC 60947-4-1
Logic input number 4
Input current 3.1 mA 100 V
7.5 mA 240 V
Current state 0 guaranteed Logic input 0…40 V 2…15 mA 25 ms
Current state 1 guaranteed Logic input 79…264 V <= 15 mA 25 ms
maximum output switching frequency 2 Hz
Maximum operating rate 1800 cyc/h
Contacts type and composition Without
Metering type Imbalance voltage
Active power P, P1, P2, P3
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Voltage U21, U32, U13, V1, V2, V3
Reactive power Q, Q1, Q2, Q3
Frequency
Power factor
Measurement accuracy 1 % voltage 100…830 V)
3 % power factor
5 % active and reactive power
Overvoltage category III
Connection pitch 0.20 in (5.08 mm)
Connections – terminals Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)solid without cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)solid without cable end
Tightening torque Control circuit 4.4…5.3 lbf.in (0.5…0.6 N.m) flat 0.1 in (3 mm)
Pollution degree 3
Electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width 1.8 in (45 mm)
Height 2.4 in (61 mm)
Depth 4.8 in (120.7 mm)
Net Weight 0.46 lb(US) (0.21 kg)
Compatibility code LTME
Environment
Standards CSA C22.2 No 14
IACS E10
IEC 60947-4-1
UL 508
EN 60947-4-1
Product Certifications LROS (Lloyds register of shipping)
ATEX
NOM
EAC
RMRoS
GL
UL
DNV
BV
RINA
KERI
C-tick
CSA
CCC
ABS
IP Degree of Protection IP20
Protective treatment 12 x 24 hour cycles EN/IEC 60068-2-30
48 h EN/IEC 60070-2-11
TH EN/IEC 60068
Fire resistance 1202 °F (650 °C) EN/IEC 60695-2-12
1760 °F (960 °C) UL 94
Ambient air temperature for operation -4…140 °F (-20…60 °C)
Ambient Air Temperature for Storage -40…176 °F (-40…80 °C)
Operating altitude <= 6561.68 ft (2000 m) without derating
Mechanical robustness Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6
Vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6
Ordering and shipping details
Category US10I1222338
Discount Schedule 0I12
GTIN 3389119404938
Returnability Yes
Country of origin CN
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.2 in (5.5 cm)
Package 1 Width 2.8 in (7.2 cm)
Package 1 Length 5.4 in (13.6 cm)
Package 1 Weight 7.05 oz (200 g)
Unit Type of Package 2 S02
Number of Units in Package 2 20
Package 2 Height 5.9 in (15 cm)
Package 2 Width 11.8 in (30 cm)
Package 2 Length 15.7 in (40 cm)
Package 2 Weight 9.667 lb(US) (4.385 kg)
Contractual warranty
Warranty 18 months
Peso 0.2 kg
Dimensiones 7.2 × 13.6 × 5.5 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LTMEV40FM, Extension module, TeSys T, 4 inputs, 100 to 240VAC, for LTMR controller”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart