Motor controller, TeSys T, Motor Management, Profibus DP, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC
LTMR27PFM
Range | TeSys |
---|---|
Product name | TeSys T |
Device short name | LTMR |
Product or Component Type | Motor controller |
Device Application | Equipment monitoring and control |
Measurement current | 1.35…27 A |
[Us] rated supply voltage | 100…240 V AC 50/60 Hz |
Current Consumption | 8…62.8 mA |
Supply voltage limits | 93.5…264 V AC |
Communication Port Protocol | Profibus DP |
Bus type | Profibus DP polarised 2-wire RS485 1…125 9.6 kbit/s…12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A Profibus DP polarised 2-wire RS485 1…125 9.6 kbit/s…12 Mbit/s, terminal block 2 shielded twisted pairs, type A |
[Ui] rated insulation voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
---|---|
[Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 |
Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
Associated fuse rating | 4 A gG output 0.5 A gG control circuit |
Protection Type | Load fluctuation Thermal protection Locked rotor Reverse polarity protection Phase unbalance Earth-leakage protection Overload (long time) Thermal overload protection Overload Phase failure Power factor variation |
Network and machine diagnosis type | Phase fault and earth fault trip counters Trip history information Trip context information Motor control command recording Running hours counter/operating time Waiting time after overload tripping Remaining operating time before overload tripping Fault recording Starting current and time Event recording |
Logic input number | 6 |
Input current | 3.1 mA 100 V 7.5 mA 240 V |
Current state 0 guaranteed | Logic input 0…40 V <= 15 mA 25 ms |
Current state 1 guaranteed | Logic input 79…264 V >= 2 mA 25 ms |
maximum output switching frequency | 2 Hz |
Load current | 5 A 250 V AC logic output 5 A 30 V DC logic output |
Permissible power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Maximum operating rate | 1800 cyc/h |
Contacts type and composition | 1 NO + 1 NC fault signal 3 NO |
Metering type | Average current Iavg Temperature Earth-fault current Phase current I1, I2, I3 RMS Imbalance current |
Measurement accuracy | 5…15 % earth fault current internal measurement 1 % voltage 100…830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power |
Overvoltage category | III |
Connection pitch | 0.20 in (5.08 mm) |
Connections – terminals | Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible with cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)flexible without cable end Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible without cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)solid without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)flexible with cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24…AWG 14)flexible without cable end Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24…AWG 14)flexible without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)solid without cable end |
Tightening torque | Control circuit 4.4…5.3 lbf.in (0.5…0.6 N.m) flat 0.1 in (3 mm) |
Pollution degree | 3 |
Electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 |
Width | 3.6 in (91 mm) |
Height | 2.4 in (61 mm) |
Depth | 4.8 in (122.5 mm) |
Net Weight | 1.17 lb(US) (0.53 kg) |
Web services | Web server |
Compatibility code | LTMR |
Standards | EN 60947-4-1 UL 508 IACS E10 CSA C22.2 No 14 IEC 60947-4-1 |
---|---|
Product Certifications | BV CSA CCC EAC NOM KERI ABS RMRoS LROS (Lloyds register of shipping) UL RINA DNV GL C-tick ATEX |
Protective treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068 |
Fire resistance | 1202.0000000000 °F (650 °C) EN/IEC 60695-2-12 1760.0000000000 °F (960 °C) UL 94 |
Ambient air temperature for operation | -4.0000000000…140.0000000000 °F (-20…60 °C) |
Ambient Air Temperature for Storage | -40.0000000000…176.0000000000 °F (-40…80 °C) |
Operating altitude | <= 6561.68 ft (2000 m) without derating |
Mechanical robustness | Vibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
IP Degree of Protection | IP20 |
Category | US10I1222338 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389119404839 |
Returnability | No |
Country of origin | CN |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.8 in (7.2 cm) |
Package 1 Width | 3.9 in (10.0 cm) |
Package 1 Length | 5.4 in (13.6 cm) |
Package 1 Weight | 18.5 oz (525.0 g) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 10 |
Package 2 Height | 5.9 in (15.0 cm) |
Package 2 Width | 11.8 in (30.0 cm) |
Package 2 Length | 15.7 in (40.0 cm) |
Package 2 Weight | 12.315 lb(US) (5.586 kg) |
Warranty | 18 months |
---|