Programmable receiver, Harmony XB5R, 4 PNP, 2 buttons, 6 indicating LEDs, monostable, 24V DC
ZBRRC
Range of Product | Harmony |
---|---|
Product or Component Type | Programmable receiver |
Device short name | ZBRRC |
Product Specific Application | Interface to PLC |
Function of module | Monostable |
Reset time | 2 ms time delay |
Transmission frequency | 2405 MHz |
emission class | 5M00G7W |
Antenna type | Omnidirectional |
Output Type | Transistor PNP |
---|---|
Output contacts | 4 PNP |
Time delay range | 0.5 s – 15…15 %) |
Maximum switching current | 0.2 mA DC |
Minimum switching current | 10 mA 5 V DC |
[Us] Rated Supply Voltage | 24 V DC – 15…20 % |
Maximum voltage drop | <2 V DC 2 A |
Communication port protocol | Zigbee green power 2.4 GHz IEEE 802.15.4 |
Maximum sensing distance | 328.08 ft (100 m) in free field 82.02 ft (25 m) transmitter in a plastic box type XAL D and receiver in a metal enclosure 131.2 ft (40 m) transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna |
Response Time | < 30 ms after transmitter clicks |
Utilisation category | DC-13 IEC 60947-5-1 |
Maximum power consumption in VA | 20 VA DC |
Maximum power consumption in W | 20 W DC |
Breaking capacity | 4.8 W per output) |
Short-circuit protection | 0.4 A fuse fast blow |
Operating position | Any position without derating |
Electrical connection | 1 conductor cable 0.0002…0.004 in² (0.14…2.5 mm²) – AWG 26…AWG 14 – solid – without cable end IEC 60947-1 2 conductors cable 0.0002…0.002 in² (0.14…1.5 mm²) – AWG 26…AWG 16 – solid – without cable end IEC 60947-1 1 conductor cable 0.0002…0.006 in² (0.14…4 mm²) – AWG 26…AWG 12 – flexible – with cable end IEC 60947-1 2 conductors cable 0.0002…0.002 in² (0.14…1.5 mm²) – AWG 26…AWG 16 – flexible – with cable end IEC 60947-1 |
Tightening torque | 4.4…8.9 lbf.in (0.5…1 N.m) IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Status LED | 1 LED Green power ON 1 LED green and yellow reception signal 4 LEDs Green relay ON |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 Mounting plate |
Rated short-duration power frequency withstand voltage | 1 kV 50 Hz IEC 60947-5-1 |
[Uimp] rated impulse withstand voltage | 0.8 kV |
Surge withstand | 0.5 kV differential mode IEC 61000-4-5 1 kV common mode IEC 61000-4-5 |
Max power consumption in W | 1 mW |
Number of channels | 1 |
modulation technique | O-QPSK |
Bandwidth | 5 MHz |
Antenna gain | 0 dBi |
Width | 1.4 in (36 mm) |
Height | 4.3 in (108 mm) |
Depth | 3.0 in (75 mm) |
Net Weight | 0.29 lb(US) (0.13 kg) |
Standards | IEC 60947-5-1 |
---|---|
Radio agreement | RSS SRRC ANATEL ARIB T66 FCC ICASA |
Product Certifications | CCC CSA GOST C-tick UL |
marking | CE |
Ambient Air Temperature for Storage | -40.0000000000…158.0000000000 °F (-40…70 °C) |
Relative humidity | 90 % -4.0000000000…131.0000000000 °F (-20…55 °C), without condensation ETSI EN 300 440-1 |
Vibration resistance | +/- 7.5 mm 5…14 Hz)IEC 60068-2-6 2 gn 8…150 Hz)IEC 60068-2-6 |
Shock resistance | 10 gn 16 ms) 6000 shocks IEC 60068-2-27 |
IP degree of protection | IP20 IEC 60529 casing) IP20 terminals) |
Pollution degree | 2 IEC 60664-1 |
Overvoltage category | III IEC 60664-1 |
Insulation resistance | > 500 MOhm 500 V DC NF C 20-030 |
[Ui] rated insulation voltage | 60 V IEC 60664-1 |
Electromagnetic compatibility | Immunity for industrial environments conforming to IEC 61000-6-2 Conducted and radiated emissions class B conforming to CISPR 22 Electrostatic discharge immunity test – test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields – test level: 10 V/m (80…2000 MHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 3 V/m (80…2700 MHz, distance = 20 m) conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test – test level: 2 kV (power supply wires) conforming to IEC 61000-4-4 Conducted RF disturbances – test level: 10 V conforming to IEC 61000-4-6 Radiated emission conforming to ETSI EN 300 440-1 Conducted emission conforming to EN 300-489-1 Conducted emission conforming to ETSI EN 300 489-3 Radiated emission conforming to ETSI EN 300 440-2 Electrical fast transient/burst immunity test – test level: 1 kV (PNP output wires) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test – test level: 0.5 kV (differential mode) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (common mode) conforming to IEC 61000-4-5 Immunity to microbreaks and voltage drops – test level: 7 ms conforming to IEC 61000-4-11 |
Category | US1000I22470 |
---|---|
Discount Schedule | 000I |
GTIN | 3606480334719 |
Returnability | Yes |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 1.8 in (4.6 cm) |
Package 1 Width | 3.1 in (7.9 cm) |
Package 1 Length | 3.8 in (9.6 cm) |
Package 1 Weight | 4.3 oz (122.0 g) |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 64 |
Package 2 Height | 11.8 in (30.0 cm) |
Package 2 Width | 11.8 in (30.0 cm) |
Package 2 Length | 15.7 in (40.0 cm) |
Package 2 Weight | 18.735 lb(US) (8.498 kg) |
Warranty | 18 months |
---|