Voltage type for actuating |
AC/DC |
Rated control supply voltage at AC 50 Hz |
110 V |
Rated control supply voltage at AC 60 Hz |
110 V |
Rated control supply voltage at DC |
110 V |
Type of electrical connection of main circuit |
Screw connection |
Rated impulse withstand voltage (Uimp) |
12 kV |
Current (Ie), max |
140 A |
Optional overload relays |
Electronic |
Current rating |
115 A |
Main current circuit resistance |
0.42 mOhm |
Rated filament current |
140 A @ 230/240V, AC-5b |
Rated isolation voltage (Ui) |
600V @ UL, CSA |
Auxiliary contacts |
IP20 IEC 60529/DIN 40050 |
Rated power (enclosed) |
50 Hp @ 230V, 3-phase per UL/CSA |
Rated operational current for contactor |
96 A @ 460V, elevator duty (UL/CSA) |
Rated power for contactor |
75 Hp @ 575V, elevator duty (UL/CSA) |
General purpose current (enclosed) |
220 A per UL/CSA |
Power dissipation |
24.6 W @ 400V, AC-3, Ie |
Operating time |
9…18 ms @ RC module, closing delay |
Short time withstand (Icw) |
1360v A for 10 s, 60 °C (140 °F) |
Coil consumption, hold-in |
8 W @ DC control |
Coil consumption, pick-up |
650VA/310 W @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of 3-phase Capacitors |
Single capacitor: 73 kVAR @ 240V, AC-6b, 50 Hz, 40 °C |
Total power dissipation |
DC control (electronic coil): 30.6 W @ 400V, AC-3, Ie |
Operating limits, dropout |
(0.3…0.6) x Us @ DC control |
Switching of lamps |
Gas discharge lamps, open: 225 A @ 40 °C (104 °F), AC-5a |
Insulation class of the coil |
Class B per VDE 0660, table 22 |
Rating for switching AC motors |
82 kW @ 415V, 50 Hz, 3-phase (AC-2, AC-3) |
Switching of hermetically sealed cooling compressor motors |
210 A @ 690V, AC-8a (manual reset of overload release (50 Hz)) |
Operating limits, pick-up |
(0.85…1.1) x Us @ DC control |
BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 250 A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating |
350 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated voltage (Ue) |
690V @ AC, 50/60 Hz |
DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 250 A @ 690V, 50 kA available fault current |
Coil voltage |
110-130V 50/60 Hz/110-130V DC electronic coil w/ electronic interface |
Rated operational current (Ie) |
Electronic-EI coil type: 242 A @ 500V, star-delta starting (50 Hz) |
UL class J and CSA HRCI-J fuses rating |
Type2 (IEC60947-4-1): 250 A @ 100 kA available fault current per UL verified combination |
UL inverse-time circuit breaker |
200 A @ 600Y/347V, 25 kA available fault current per UL listed combination |
Switching of power transformers |
Apparent power: 87.3 kVA @ 480V, AC-6a, 60 Hz |
Rated operational power (Pe) |
98 kW @ 500V, AC-4 (50 Hz), ambient temperature 60 °C |
Switching of DC loads |
3-Poles in series: 210 A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Optional accessories |
Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks |
Features |
Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil) |
Contacts |
3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks |
Conventional coil type |
Yes |
Electronic-EI coil type |
Yes |
Rated coil frequency |
AC 50 Hz, 50/60 Hz DC |