Voltage type for actuating |
AC |
Rated control supply voltage at AC 50 Hz |
110 V |
Rated control supply voltage at AC 60 Hz |
120 V |
Current (Ie), max |
97 A |
Switching frequency, max |
200 ops/h |
Main current circuit resistance |
2 mohm |
Cross section per UL/CSA |
16 |
Rated operational current for contactor at elevator duty (UL/CSA) |
28.0A @ 230V |
Rated operational power for contactor at elevator duty (UL/CSA) |
7.5Hp @ 200V |
Rated isolation voltage (Ui) |
690V @ IEC |
Rated voltage (Ue) |
690V @ AC, 50/60 Hz |
Rated operational power for contactor at wye-delta |
40Hp @ 575V, 60 Hz |
Rated filament current |
37A @ 230/240V, AC-5b |
Power dissipation |
8.2 W @ 400V, AC-3, Ie |
Coil terminal conductor cross section |
1…4 mm² @ 2 conductor |
Rated current (enclosed) |
34A @ 115V, 1-phase per UL/CSA |
Rated power (enclosed) |
5Hp @ 230V, 1-phase per UL/CSA |
Coil consumption pick-up (avg/peak) |
14/22 W @ DC (electronic-EA) |
General purpose current (enclosed) |
60 A per UL/CSA |
Capacitance, max |
540 µF @ short-circuit current of 50 kA |
Switching of low inductive loads |
45A @ 440V, AC-7a per IEC 61095 (50 Hz) |
Operating limits, pick-up |
(0.85…1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Short time withstand (Icw) |
304A @ 10s, 60 °C |
Coil consumption, hold-in |
3 W @ DC (electronic-EA) |
Coil consumption, pick-up |
105VA @ 50 Hz, 60 Hz, 50/60 Hz |
Operating time |
15…30 ms @ AC closing delay |
Total power dissipation |
DC control (electronic): 9.9 W @ 400V, AC-3, Ie |
Operating limits, dropout |
(0.3…0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of lamps |
Gas discharge lA, open: 45A @ 40°C (104 °F), AC-5a |
Switching of hermetically sealed cooling compressor motors |
45A @ 500V, AC-8a (manual reset of overload release (50 Hz)) |
Coil insulation class |
Class F per IEC 60085, UL Class 105 |
Rating for switching AC motors |
3-poles: 5Hp @ 230V (AC-2, AC-3, AC-4), 1-phase (60 Hz) |
BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 80A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating |
125A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
UL inverse-time circuit breaker |
50 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated operational current (Ie) |
66 A @ ≤240V, Star-Delta starting (50 Hz) |
Rated operational power (Pe) |
78 kW @ 690V, AC-1 active power load (50 Hz), ambient temperature 60 °C |
DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 80A @ 690V, 50 kA available fault current |
UL class J and CSA HRCI-J fuses rating |
50A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14 |
Switching of power transformers |
Apparent power: 8.3 kVA @ 240V, AC-6a 60 Hz (n = 30) |
Switching of 3-phase Capacitors |
Single capacitor: 25 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH) |
Switching of DC loads |
3-Poles in series: 45A @ 48/60V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Contacts |
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9…23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block |
Function |
Reversing contactor |
Rated impulse voltage withstand (Uimp) |
6 kV |
Conventional coil type |
True |
Electronic-EI coil type |
True |
Rated coil frequency |
AC 50/60 Hz, DC |