Voltage type for actuating |
AC |
Rated control supply voltage at AC 50 Hz |
200 V |
Rated control supply voltage at AC 60 Hz |
208 V |
Current (Ie), max |
97 A |
Switching frequency, max |
200 ops/h |
Main current circuit resistance |
1.5 mOhm |
Cross section per UL/CSA |
16 AWG |
Rated operational current for contactor at elevator duty (UL/CSA) |
34.0 A @ 460V |
Rated operational power for contactor at elevator duty (UL/CSA) |
30 Hp @ 575V |
Rated isolation voltage (Ui) |
690V @ IEC |
Rated voltage (Ue) |
690V @ AC, 50/60 Hz |
Rated operational power for contactor at wye-delta |
50 Hp @ 575V, 60 Hz |
Rated filament current |
43 A @ 230/240V, AC-5b |
Power dissipation |
8.3 W @ 400V, AC-3, Ie |
Coil terminal conductor cross section |
1…4 mm^2 @ 2 conductor |
Rated current (enclosed) |
40 A @ 230V, 1-phase per UL/CSA |
Rated power (enclosed) |
7.5 Hp @ 230V, 1-phase per UL/CSA |
Coil consumption pick-up (avg/peak) |
18/29 W @ DC (electronic-EA) |
General purpose current (enclosed) |
75 A per UL/CSA |
Capacitance, max |
640 µF @ short-circuit current of 50 kA |
Switching of low inductive loads |
63 A @ 440V, AC-7a per IEC 61095 (50 Hz) |
Operating limits, pick-up |
(0.85…1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Short time withstand (Icw) |
375 A for 10 s, 60 °C |
Coil consumption, hold-in |
4 W @ DC (electronic-EA) |
Coil consumption, pick-up |
135VA @ 50 Hz, 60 Hz, 50/60 Hz |
Operating time |
15…30 ms @ AC closing delay |
Total power dissipation |
DC control (electronic): 10.8 W @ 400V, AC-3, Ie |
Operating limits, dropout |
(0.3…0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of lamps |
Gas discharge lamps, open: 77 A @ 40 °C (104 °F), AC-5a |
Switching of hermetically sealed cooling compressor motors |
63 A @ 500V, AC-8a (manual reset of overload release (50 Hz)) |
Coil insulation class |
Class F per IEC 60085, UL Class 105 |
Rating for switching AC motors |
3-poles: 7.5 Hp @230V (AC-2, AC-3, AC-4), 1-phase (60 Hz) |
BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 80 A @ 415V, 65 kA available fault current |
UL class K5 and RK5 fuses rating |
150 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
UL inverse-time circuit breaker |
50 A @ 600Y/347V, 25 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated operational current (Ie) |
85 A @ 690V, AC-1 active power load (50 Hz), ambient temperature 40 °C |
Rated operational power (Pe) |
75 kW @ 690V, AC-1 active power load (50 Hz), ambient temperature 60 °C |
DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 100 A @ 690V, 50 kA available fault current |
UL class J and CSA HRCI-J fuses rating |
70 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Switching of power transformers |
Apparent power: 9.6 kVA @ 240V, AC-6a 60 Hz (n = 30) |
Switching of 3-phase Capacitors |
Single capacitor: 35 kVAR @ 690V, AC-6b 50 Hz, 40 °C (Inductance of leads between capacitors in parallel: min. 6 µH) |
Switching of DC loads |
3-Poles in series: 63 A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C) |
Contacts |
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9…23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block |
Function |
Reversing contactor |
Rated impulse voltage withstand (Uimp) |
6 kV |
Conventional coil type |
Yes |
Electronic-EI coil type |
Yes |
Rated coil frequency |
AC 50/60 Hz, DC |
There are no reviews yet.