Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

104S-C16EJ210BC, IEC 16 A SC Safety Contactor

MXN $999,999.00 - (IVA Incluido) + Envío

2 disponibles

IEC 16 A SC Safety Contactor

Comprar Ahora
SKU: 104S-C16EJ210BC
Auxiliary Contact Cnfg 1 NO / 5 NC
Coil Code 24V50/60Hz/24V DC Elec Cl
Maximum Ampere Rating 16 A
Voltage type for actuating DC
Rated control supply voltage at AC 50 Hz 0 V
Rated control supply voltage at AC 60 Hz 0 V
Rated control supply voltage at DC 24 V
Current (Ie), max 16 A
Switching frequency, max 220 ops/h
Main current circuit resistance 2.7 mohm
Cross section per UL/CSA 16
Rated operational current for contactor at elevator duty (UL/CSA) 5Hp @ 230V
Rated isolation voltage (Ui) 690V @ IEC
Rated voltage (Ue) 690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta 7.5Hp @ 200V, 60 Hz
Rated filament current 18A @ 230/240V, AC-5b
Power dissipation 2.1 W @ 400V, AC-3, Ie
Coil terminal conductor cross section 1…4 mm² @ 2 conductor
Rated current (enclosed) 17.5A @ 200V, 3-phase per UL/CSA
Rated power (enclosed) 5Hp @ 230V, 3-phase per UL/CSA
Coil consumption pick-up (avg/peak) 14/22 W @ DC (electronic-EA)
General purpose current (enclosed) 30 A per UL/CSA
Capacitance, max 500 µF @ short-circuit current of 20 kA
Switching of low inductive loads 32A @ 440V, AC-7a per IEC 61095 (50 Hz)
Operating limits, pick-up (0.85…1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of motor load 19A @ 230V, AC-7b per IEC 61095 (50 Hz)
Short time withstand (Icw) 170A @ 10s, 60 °C
Coil consumption, hold-in 9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up 75VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time 20…50 ms @ DC (electronic) opening delay
Total power dissipation DC control (electronic): 3.8 W @ 400V, AC-3, Ie
Operating limits, dropout (0.3…0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps Gas discharge lA, open: 28A @ 40°C, AC-5a
Switching of hermetically sealed cooling compressor motors 9.3A @ 690V, AC-8b (manual reset of overload release (50 Hz))
Coil insulation class Class F per IEC 60085, UL Class 105
Rating for switching AC motors 7.5 kW @ 690V @ 50Hz, 3-phase (AC-2, AC-3, AC-4)
BS88 fuses current rating Type 2 (per IEC 60947-4-1): 32A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating 70A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class CC and CSA HRCI-MISC fuses rating 30A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker 50A @ 480V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
Coil voltage 24V DC electronic coil
Rated operational current (Ie) 9A @ 690V, AC-4 (approximately 200000 ops)
Rated operational power (Pe) 7.5 kW @ 690V, AC-4 (approximately 200000 ops)
DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 35A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating 30A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers Apparent power: 9.4 kVA @ 500V, AC-6a @ 50Hz (n = 30)
Switching of 3-phase Capacitors Single capacitor: 8.5 kVAR @ 240V, AC-6b, 50 Hz, 60 °C (inductance of leads between capacitors in parallel: minimum 6 µH)
Switching of DC loads 3-pole:32A @ 110V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Contacts 3 main poles with NC mechanically linked or mirror ftdback contacts
Function Reversing contactor
Rated impulse voltage withstand (Uimp) 6 kV
Conventional coil type True
Electronic-EI coil type True
Rated coil frequency AC 50/60 Hz, DC
Ripple, max ±15% @ DC (electronic)
OFF time, min 50 ms @ DC (electronic)
Width 98.8 mm
Height 80.77 mm
Depth 115.62 mm
Auxiliary contact type Bifurcated contact
Options No options selected
Optional accessories Side-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
Features Positively guided/mechanically linked auxiliary contacts, front-mounted auxiliary contacts: permanently fixed, protective cover to prevent manual ops, red contact housing for easy identification, incorporates IEC 947-5-1 “Mechanically Linked” symbol
Recommended torque 9 in-lb
Coil termination Line side connection
Conductor cross section Main contact, 2 conductor: 1.5…6 mm²
Lifespan Mechanical DC control: 13000000 ops
Weight 0.87 kg (1.91 lbs) reverse @ DC (electronic-EQ, EJ)
Type of electrical connection of main circuit Screw connection
Auxiliary contacts 1 NO/5 NC
Altitude of installation site, max 2000 m (NN), per IEC60947-1
Protection against accidental contact Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature Storage: -55…80 °C (-67…176 °F)
Protection class, auxiliary contact IP2X
Resistance to vibration IEC 60068-2-6
Resistance to shock IEC 60068-2-27
Peso 1.168 kg
Dimensiones 17.09 × 13.1 × 23.19 cm
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
General Short Circuit Ratings Data Sheet --
General Product Cutsheet --
General Repair Parts List --
Technical Data 100-td013_-en-p 100-TD013
,
Short Circuit Ratings Data Sheet General
--
Product Cutsheet General
--
Repair Parts List General
--
100-td013_-en-p Technical Data
100-TD013
,

Customers reviews

There are no reviews yet.

Be the first to review “104S-C16EJ210BC, IEC 16 A SC Safety Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart