| Adj. Thermal Current Range (A) | 0.4 – 0.63A,MxRtg MCPs(no OvPrt)is 1200.0A |
|---|---|
| Circuit Breaker Type | Mtr Prt Circuit Breaker |
| With integrated auxiliary switch | False |
|---|---|
| With integrated under voltage release | False |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 100 kA |
| Rated operation power at AC-3, 400 V | 0.18 kw |
| Rated permanent current Iu | 0.63 A |
| Rated operation power at AC-3, 230 V | 0.09 kw |
| Rated operating voltage | 230 A |
| Type of control element | Turn button |
| Overload release current setting | 0.4 A |
| Type of electrical connection of main circuit | Screw connection |
| Magnetic release current per IEC | 13 A |
| Rated operational current (Ie) per IEC | 0.63 A |
| Magnetic trip current | 13 A |
| Rated supply current (Ie) | 0.1 A |
| Short circuit current (Icu) for group motor installation, max | 65kA @ 480V |
| Current range | 0.40 to 0.63 A |
| Ultimate short circuit breaking capacity (Icu) per IEC | 100kA @ 690V |
| Rated service short circuit breaking capacity (Ics) per IEC | 100kA @ 690V |
| Hp rating, max | 0.33Hp @ 575V, 3-phase |
| Rated insulation voltage (Ui) | 690V per IEC, SEV, VDE0660 |
| Electrical life cycle | 100000 ops (Ie maximum) |
| Switching of standard motors per IEC | 0.25 kW @ 690V (AC-3), 3-phase |
| KW rating, max | 0.25 kW @ 690V (AC-3), 3-phase |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | No back-up fuse required @ 690V |
| Short circuit current (Type 2 coordination), max | 65kA @ 480V |
| Total power loss (Pv) for circuit breaker | 6…11.5 W @ rated load operating temperature |
| Rated thermal current (Ith) | 0.1…32A @ 60°C ambient temperature |
| Short circuit current for tap conductor protection, max | 65 kA @ 480Y/277V per UL 508-manual motor controller |
| Short circuit current for combination motor controller, max | 65kA @ 480V/277V per UL 508-self-protected (Type E) |
| Fuse or circuit breaker per NEC, max | 450 A, UL 508-manual motor controller |
| Rated impulse withstand voltage (Uimp) | Main circuits/overvoltage category: 6 kV/III |
| Short circuit current for group motor installation, max | 65kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect, max | 65kA @ 480V, UL 508-manual motor controller |
| Magnetic release current | Fixed setting 16…21 x Ie max. Ie max. = maximum values of setting ranges (±20 %) |
| Number of poles | 3 |
| With thermal protection | True |
| Phase failure sensitive | True |
| Switch off technique | Thermomagnetic |
| Switching frequency, max | 25 ops/h |
| Trip class | 10 |
| Rated frequency | 50/60 Hz |
| Phase loss protection | Differential release |
| Width | 45 mm |
|---|---|
| Depth | 70 mm |
| Height | 90 mm |
| Frame size | Frame size C, 32 A |
| Contactor size (Type 2 coordination), min | 100-C09 @ 600V |
| Device construction | Built-in device fixed built-in technique |
| Degree of protection (IP) | IP2X |
|---|---|
| Weight | 315 lb |
| Mechanical life operations | 100000 /h |
| Breaking capacity | Standard breaking capacity |
| Shock | Transport (60068-2-27): 30 G, 11 ms, all axes |
| Protection type | Adjustable thermal/fixed magnetic (fixed at 16…20 x In) |
| Factory option | No circuit-breaker auxiliary or trip contacts |
| Vibration | Ops (60068-2-6): 5 G |
| Ambient storage temperature | -40 °C |
|---|---|
| Ambient operating temperature | -25 °C |
| Site altitude | 2000 m (NN) |
| Moisture heat | 40 °C, relative humidity 93 %, 56 d, (60068-2-3) |
| Dry heat | 100 °C, relative humidity < 50 %, 7 d, (60086-2-2) |
| Dependence on temperature | No current reduction @ 60 °C |
| Moisture change climate | 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles, (600068-2-30) |
| Pollution degree | 3 |
| Ambient temperature compensation, max | -20 °C |
| Utilization category | Motor starter: AC-3 (IEC60947-4-1) |
|---|---|
| Overload protection characteristics | IEC 60947-4-1 motor protection |