Necesitas Ayuda?+52 55 61 22 77 00
Correo: ventas@omegaautomation.com.mx

140M-F8E-C45-CX-KY, Motor Protection Circuit-Breaker

MXN $999,999.00 - (IVA Incluido) + Envío

2 disponibles

Motor Protection Circuit-Breaker

Comprar Ahora
SKU: 140M-F8E-C45-CX-KY
Adj. Thermal Current Range (A) 32 – 45A,MxRtg MCPs(no OvPrt)is 1200.0A
Circuit Breaker Type Mtr Prt Circuit Breaker
With integrated auxiliary switch False
With integrated under voltage release False
Rated short-circuit breaking capacity lcu at 400 V, AC 65 kA
Rated operation power at AC-3, 400 V 22 kw
Rated permanent current Iu 45 A
Rated operation power at AC-3, 230 V 13 kw
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 32 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 585 A
Magnetic trip current, nom 585 A
Rated operational current (Ie) per IEC 45 A
Rated supply current (Ie) 6.3 A
Short circuit current (Icu) for group motor installation, max 65kA @ 480V
Short circuit current (Type 2 coordination) with 100-C IEC contactor, max 65kA @ 480V
Current range 32…45 A
Ultimate short circuit breaking capacity (Icu) per IEC 65kA @ 400/415V AC
Rated service short circuit breaking capacity (Ics) per IEC 6kA @ 690V AC
Insulation voltage (Ui) Rated 690V per IEC
Hp rating, max 40Hp @ 575V, 3-phase
Electrical life cycle 30000 ops (Ie maximum)
Short circuit current for self-protected combination motor controller with 100-C contactor, max 65 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 40 kW @ 690V (AC-3), 3-phase
KW rating, max 40 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 230/240V AC
Short circuit current for combination motor controller with 100-C IEC contactor, max 65 kA @ 480Y/277V, UL 60947-4-1-Type F
Total power loss (Pv) for circuit breaker 7…22 W @ rated load/operating temperature
Short circuit current for group motor installation with 100-C IEC contactor, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Short circuit current for motor disconnect with 100-C IEC contactor, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Rated thermal current (Ith) 6.3…45 A up to 60 °C (140 °F) ambient temperature
Short circuit current for tap conductor protection, max 65 kA @ 480Y/277V, UL 60947-4-1-manual motor controller
Short circuit current for combination motor controller, max 65kA @ 480V/277V, UL 60947-4-1 self-protected (Type E)
Fuse or circuit breaker per NEC, max 600 A, UL 60947-4-1-manual motor controller
Rated impulse withstand voltage (Uimp) Main circuits (Uimp)/overvoltage category: 6 kV/III, 8 kV (disconnect)
Short circuit current for group motor installation, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Short circuit current for motor disconnect, max 65kA @ 480V, UL 60947-4-1-manual motor controller
Number of poles 3
With thermal protection True
Phase failure sensitive True
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 45 Hz
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-C IEC contactor per NEC, max 600 A, UL 60947-4-1-manual motor controller
Width 54 mm
Depth 110 mm
Height 111.4 mm
Contactor size (Type 2 coordination) with 100-C IEC contactor, min 100-C37 @ 600V
Frame size Frame size F, 45 A
Contactor size, min 100-C37, UL-508 -Type E self-protected combination motor controller
Device construction Built-in device fixed built-in technique
Degree of protection (IP) IP2X
Weight 782 lb
Mechanical life operations 30000 /h
Breaking capacity High breaking capacity
Shock Transport (60068-2-27): 30 G/11 ms, OFF
Protection type Adjustable thermal/fixed magnetic (13 x In)
Factory option No circuit-breaker auxiliary or trip contacts
Vibration Ops (60068-2-6): 5 G
Ambient storage temperature -40 °C
Ambient operating temperature -25 °C
Ambient temperature compensation -25 °C
Site altitude To 2000 m N.N. (6561 ft)
Dependence on temperature No reduction @ 60 °C (140 °F)
Magnetic release current (±20 %) Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version
Pollution degree 3
Climatic resistance Operating humidity/moisture heat (60068-2-3): 5…95% non-condensing
Utilization category Motor starter: AC-3 (IEC60947-4-1)
Overload protection characteristics IEC 60947-4-1 motor protection
Peso 1.814 kg
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
Technical Data 140m-td002_-en-p 140M-TD002
,
140m-td002_-en-p Technical Data
140M-TD002
,

Customers reviews

There are no reviews yet.

Be the first to review “140M-F8E-C45-CX-KY, Motor Protection Circuit-Breaker”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart