150-C9NCD, SMC-3 9A Smart Motor Controller

MXN $20,540.30 - (IVA Incluido) + Envío

2 disponibles

SMC-3 9A Smart Motor Controller

Comprar Ahora
SKU: 150-C9NCD
With display False
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current 3 A
Controller type SMC-3
DV/DT protection 1000V/µs for power circuit
Repetitive peak voltage 1600V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Line connected motor power, max 5.5 kW @ 500V AC @ 50Hz, 3-phase
Delta connected motor power, max 3…7.5 kW @ 500V AC @ 50Hz, 3-phase
Overvoltage category III per IEC for side mount auxiliary contacts
Rated impulse voltage 6 kV for power circuit
Dielectric withstand 2500V AC per IEC for power circuit
Line connected motor current 3…9A @ 500/575V AC, 3-phase
Delta connected motor current 5.1…16A @ 500/575V AC, 3-phase
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Input OFF-state current <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
High capacity available fault current, max 69kA @ 600V, maximum current 30 A time delay Class J or Class L fuse for inside delta connected motors
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Standard controller feature Soft stop
Standard available fault current, max 5 kA @ maximum standard fuse 60 A for delta device opsal current rating
Integrated motor overload protection True
Short circuit protection device performance (SCPD) type Type 1
Selectable overload trip class Trip Class 10, 15, or 20
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Degree of protection (IP) IP2X
Weight 0.86 kg
Shock Opsal: 15 G
Width 44.8 mm (1.76 in)
Depth 110 mm (4.33 in)
Height 139.7 mm (5.5 in)
Cable size 2.5…25 mm² (14…4 AWG) for line power terminals
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Tightening torque 2.3…3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Internal bypass True
Function Single direction
Selectable kick start – 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Steady state heat dissipation 12 W
Storage and transportation temperature -25 °C
Rated surrounding temperature range without derating -5 °C
Humidity 5…95% noncondensing
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Altitude 2000 m
Pollution degree 2
Mounting hole size 4.6 mm
Number of poles Equipment is designed for 3-phase only for power circuit
Enclosure Open type
Peso 0.916 kg
Dimensiones 18.49 × 9.39 × 17.6 cm
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
General Dimension Sheet (Catalog) --
General Features and Modes of Operation --
General Dimension Sheet (PDF) --
General Wiring --
General Specifications Sheet --
General OL Trip Curves and Starts per Hour Curves --
General Product Cutsheet --
General Short Circuit Ratings Data Sheet --
Installation Instructions 150-in044_-en-e 150-IN044
Technical Data 150-td009_-en-p 150-TD009
,
Dimension Sheet (Catalog) General
--
Features and Modes of Operation General
--
Dimension Sheet (PDF) General
--
Wiring General
--
Specifications Sheet General
--
OL Trip Curves and Starts per Hour Curves General
--
Product Cutsheet General
--
Short Circuit Ratings Data Sheet General
--
150-in044_-en-e Installation Instructions
150-IN044
150-td009_-en-p Technical Data
150-TD009
,