Number Of Channels 4 Channel
Output Signal Analog
Number of analogue inputs 4
Input, current True
Input, voltage True
Input, resistor True
Input, resistance thermometer True
Input, thermocouple True
Output, current False
Output, voltage False
Analogue inputs configurable True
Analogue outputs configurable False
Type of electric connection Screw-/spring clA connection
Local CJC sensor accuracy ±0.3 °C
Input range, current 0…20mA @ 4….20mA
Remote CJC sensor accuracy Based on specified thermistor: ±0.3 °C
RTD excitation current 600 µA, 3 wire mode, 100 µA, 2 wire mode
Module keying Electronic keying via progming software
Scan time Per channel: 625 µs, Per group: 2.5 ms
Step response time to 63% of value 7.5 ms (Notch filter 10 kHz)
Module conversion method Sigma-Delta, One 24-bit multiplexed ADC
RTB torque 5069-RTB18-SCREW, 5069-RTB14CJC-SCREW: 0.4 Nm (3.5 lbin)
Overvoltage protection, max Voltage, current, RTD, and thermocouple/mV modes: ±30V DC
Common mode voltage ±10V (Current mode and 3-wire RTD mode), ±2V (Voltage mode)
Data format IEEE 32-bit floating point
Wire category 2 – shielded input ports, 2 – power ports, 1 wire per terminal for each signal port
Power dissipation, max Voltage mode: 1.8 W, Current mode: 2.1 W, RTD mode: 2.1 W, Thermocouple / mvolt mode: 1.8 W
Indicators 1 green/red module status indicator, 4 yellow/red I/O status indicators, 2 yellow/red CJC status indicators
Thermal dissipation, max Voltage mode: 6.1 BTU/hr, Current mode: 7.2 BTU/hr, RTD mode: 7.2 BTU/hr, Thermocouple/mvolt: 6.1 BTU/hr
Accuracy drift with temperature Voltage: 0.200% full scale, Current: 0.300% full scale, RTD: 0.200% full scale, Thermocouple/mvolt: 0.200% full scale
Input Total Unadjusted Error (TUE) Voltage: 0.300% full Scale, Current: 0.400% full Scale, RTD: 0.300% full Scale, Thermocouple/mvolt: 0.300% full Scale
Inputs 4 differential
Wire size 5069-RTB18-SPRING and 5069-RTB14CJCSPRING connections: 0.5…1.5 mm² (22…16 AWG) solid or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 2.9 mm (0.11 in.), max diam including insulation, single wire connection only, 5069-RTB18-S
Calibrated accuracy Voltage: 0.100% full scale @ 25 °C Current: 0.100% full scale @ 25 °C RTD: 0.100% full scale @ 25 °C Thermocouple/mvolt: 0.100% full scale @ 25 °C
Suitable for safety functions False
Notch filter frequency at RPI of 2.5 ms, min 10 khz
Input anti-aliasing filter cutoff frequency, typical 500 Hz
Onboard data alarming True
Scaling to engineering units True
Real-time channel sampling True
Thermocouple linearization ITS-90
Input range, thermocouple / millivolt ±100 mV
Common mode noise rejection ratio 130 dB @ 50/60 Hz
Overcurrent protection, max Current mode: ±30 mA
Input range, voltage ±10V @ 0…10V, 0…5V
Notch filter at minimum RPI 62.5 kHz (0.2 ms, 1 channel enabled)
Input type, thermocouple B, C, D, E, J, K, L (TXK/XK), N, R, S, T
Normal mode noise rejection ratio 65 dB @ 50/60 Hz, notch filter dependent
Input digital filter First order lag, 0 ms…32,767 ms (32.767 s)
Input range, resistive 1…500 Ω, 2…1000 Ω, 4…2000 Ω, 8…4000 Ω
Calibration methods Factory calibrated, User-performed (optional)
Data value during overload condition Full scale, overrange flag, Data uncertain / data bad
Resolution, thermocouple / millivolt 16 bit at 10 Hz notch filter: <3.1 µV/cnt in ±100 mV mode
Wire impedance 25 Ω maximum for specified accuracy (3-wire RTD mode only)
HART handheld compliance Add an external 250 Ω resistor into the current loop for HART transmitter compliance
Insulation stripping length 5069-RTB18-SPRING connections: 10 mm (0.39 in.), 5069-RTB18-SCREW connections: 12 mm (0.47 in.)
Resolution, current 16 bit at 10 Hz notch filter: 0…21 mA: <0.32 µA/count (16 bit), 3.6…21 mA: <0.27 µA/count (16 bit)
Input notch filter (Hz) selections 5, 10 (50/60 default), 15, 20, 50, 60, 100, 200, 500, 1000, 2500, 5000, 10000, 15625, 25000, 31250, 62500
Open circuit detection time, nom Voltage: + full scale, <2 s, Current: 4…20 mA range, <2 s, RTD: <2 s, Thermocouple / mvolt: + full scale, <10 s
Input type, RTD 100, 200, 500, 1000 Ω platinum, alpha=385, 100, 200, 500, 1000 Ω platinum, alpha=3916, 120 Ω nickel, alpha=672, 100, 120, 200, 500 Ω nickel, alpha=618, 10 Ω copper 427
Resolution, voltage 16 bit at 10 Hz notch filter: ±10.5V: <320 µV/count (15 bit plus sign bipolar), 0…10.5V: <160 µV/count (16 bit unipolar), 0…5.25V: <80 µ/V count (16 bit unipolar)
Resolution, RTD (16 bit at 10 Hz notch filter) 3 wire mode: <7.9 mΩ/cnt in 1…500 Ω mode, <15.8 mΩ/cnt in 2…1000 Ω mode, <31.7 mΩ/cnt in 4…2000 Ω mode, <63.4 mΩ/cnt in 8…4000 Ω mode
CJC inputs Two CJC sensors, 2 thermistors embedded in 5069-RTB14CJC-(screw or spring) RTB, -or- 2 thermistors wired to 5069-RTB18-(screw or spring) RTB, Thermistor type: Measurement specialties, Inc. 10K3A1A, (for thermocouple mode use only)
RTD sensor types/temperature range 100, 200, 500, 1000 Ω PT 385: -200…870 °C, -328…1598 °F, 73…1143 °K, 132…2058 °R, 100, 200, 500, 1000 Ω PT 3916: -200…630 °C, -328…1166 °F, 73…903 °K, 132…1626 °R, 10 Ω CU 247: -200…260 °C, -328…500 °F, 73…533 °K, 132…960 °R,
Thermocouple type/temperature range Thermocouple Type B: 21…1820 °C, 68…3308 °F, 293…2093 °K, 528…3768 °R, Thermocouple Type C: 0…2320 °C, 32…4208 °F, 273…2593 °K, 492…4668 °R, Thermocouple Type D: 0…2320 °C, 32…4208 °F, 273…2593 °K, 492…4668 °R, Thermocouple Type E: -270…1000 °C, -454…18
Width 22 mm
Height 144.57 mm
Depth 105.42 mm
Enclosure type None (open-style)
Surrounding air temperature, max 60 °C
North American temperature code T4
Operating temperature 0 °C
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±4kV @ 5kHz on power ports, ±3kV @ 5kHz on shielded input ports
Relative humidity 5…95% noncondensing
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Surge transient immunity ±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports, ±2 kV line-earth (CM) on shielded input ports
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
Nonoperating temperature -40 °C
Voltage variation 10 ms interruption on MOD power port
SA power 100mA @ 18…32V DC
SA power passthrough, max 9.95A @ 18…32V DC
MOD power 75mA @ 18…32V DC
MOD power passthrough, max 9.55A @ 18…32V DC
RTB keying None
Weight 175 g
Vibration 5 G @ 10…500 Hz
Shock Operating: 30 G, Non operating: 50 G
Slot width 1
DIN rail Compatible zinc-plated chromate-passivated steel DIN rail, You can use the EN50022 – 35 x 7.5 mm (1.38 x 0.30 in)
Input impedance Voltage: >1 MΩ, Current: 90 Ω typical, 70…110 Ω range, RTD: >1 MΩ, Thermocouple/mvolt: >1 MΩ
Isolation voltage 250V (continuous), basic insulation type, 50V Functional isolation between SA power and input ports, No isolation between individual input ports
ATEX temp code T4
IECEx temp code T4
Peso 0.24 kg
Dimensiones 13.46 × 18.79 × 5.08 cm
Marcas

Allen-Bradley

Marca

Rockwell Automation

Type Resource Publication
General User Manual 5000-UM005
General Product Cutsheet --
Technical Data 5069-td001_-en-p 5069-TD001
,
User Manual General
5000-UM005
Product Cutsheet General
--
5069-td001_-en-p Technical Data
5069-TD001
,

Customers reviews

There are no reviews yet.

Be the first to review “5069-IY4, Compact 5000 UniversalAnalog InputModule”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart