TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 110 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 4.92 inches deep. It weighs 3.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

SKU: LC1D40008F7

IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 110VAC 50/60Hz coil, open style

LC1D40008F7

Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
contactor application Resistive load
Utilisation category AC-1
poles description 4P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 60 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 2 NO + 2 NC
Protective cover Without
[Ith] conventional free air thermal current 60 A (at 140.0000000000 °F (60 °C)) for power circuit
Irms rated making capacity 800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 320 A 104.0000000000 °F (40 °C) – 10 s for power circuit
720 A 104.0000000000 °F (40 °C) – 1 s for power circuit
72 A 104.0000000000 °F (40 °C) – 10 min for power circuit
165 A 104.0000000000 °F (40 °C) – 1 min for power circuit
Associated fuse rating 80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole 5.4 W AC-1
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 60 A AC-1 <= 440 V
Control circuit type AC 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C))
160 VA 50 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
15 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 140.0000000000 °F (60 °C)
Connections – terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) – cable stiffness: flexible without cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) – cable stiffness: flexible without cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) – cable stiffness: flexible with cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) – cable stiffness: flexible with cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) – cable stiffness: solid without cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) – cable stiffness: solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm)
Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm)
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Mounting Support Plate
Rail
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product Certifications GL
LROS (Lloyds register of shipping)
GOST
UL
DNV
RINA
CSA
CCC
BV
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40.0000000000…140.0000000000 °F (-40…60 °C)
140.0000000000…158.0000000000 °F (60…70 °C) with derating
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562.0000000000 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor open 8 Gn for 11 ms)
Shocks contactor closed 10 Gn for 11 ms)
Vibrations contactor opened 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Height 5.0000000000 in (127 mm)
Width 3.3 in (85 mm)
Depth 4.9 in (125 mm)
Net Weight 3.17 lb(US) (1.44 kg)
Ordering and shipping details
Category US10I1222357
Discount Schedule 0I12
GTIN 3389110231588
Returnability Yes
Country of origin US
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.984 in (15.200 cm)
Package 1 Width 4.409 in (11.200 cm)
Package 1 Length 5.197 in (13.200 cm)
Package 1 Weight 3.206 lb(US) (1.454 kg)
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 16.854 lb(US) (7.645 kg)
Contractual warranty
Warranty 18 months
Peso 1.464 kg
Dimensiones 11.2 × 13.2 × 15.2 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC1D40008F7, IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 110VAC 50/60Hz coil, open style”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart