Product or Component Type Contactor
Device short name LC1D
contactor application Resistive load
Motor control
Utilisation category AC-3
AC-1
AC-4
AC-2
poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 50 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
80 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 440 V AC 50/60 Hz
Complementary
Motor power kW 22 kW at 380…400 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 220…230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
Maximum Horse Power Rating 3 hp at 115 V AC 60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phase motors
15 hp at 230/240 V AC 60 Hz for 3 phase motors
40 hp at 460/480 V AC 60 Hz for 3 phase motors
40 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140.0000000000 °F (60 °C)) for control circuit
80 A (at 140.0000000000 °F (60 °C)) for power circuit
Irms rated making capacity 900 A at 440 V for power circuit conforming to IEC 60947
140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit
Power dissipation per pole 3.7 W AC-3
9.6 W AC-1
[Ui] rated insulation voltage Control circuit 600 V CSA
Control circuit 600 V UL
Power circuit 600 V CSA
Power circuit 600 V UL
Control circuit 690 V IEC 60947-1
Power circuit 690 V IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC 50/60 Hz
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz
Inrush power in VA 140 VA cos phi 0.75 (at 68.0000000000 °F (20 °C))
160 VA cos phi 0.75 (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
15 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 4…19 ms opening
12…26 ms closing
Maximum operating rate 3600 cyc/h 140.0000000000 °F (60 °C)
Connections – terminals Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: rigid
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: rigid
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Terminals description ISO n°1 (21-22)NC
(A1-A2)CO
(13-14)NO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Mounting Support Plate
Rail
Environment
Standards UL 508
EN 60947-5-1
EN 60947-4-1
IEC 60947-4-1
CSA C22.2 No 14
IEC 60947-5-1
Product Certifications UL
DNV
BV
GOST
RINA
CSA
CCC
LROS (Lloyds register of shipping)
GL
IP degree of protection IP2X IEC 60529
IP2X VDE 0106
Climatic withstand IACS E10 exposure to damp heat
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562.0000000000 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor opened 10 Gn for 11 ms)
Shocks contactor closed 15 Gn for 11 ms)
Vibrations contactor opened 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Height 5.0000000000 in (127 mm)
Width 3.0 in (75 mm)
Depth 4.7 in (119 mm)
Net Weight 3.09 lb(US) (1.4 kg)
Ordering and shipping details
Category 22357-CTR,TESYS D,OPEN,40-65A AC
Discount Schedule I12
GTIN 3389110426175
Returnability No
Country of origin CZ
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.2 in (8.2 cm)
Package 1 Width 4.9 in (12.5 cm)
Package 1 Length 5.3 in (13.5 cm)
Package 1 Weight 3.192 lb(US) (1.448 kg)
Contractual warranty
Warranty 18 months
Peso 5 kg
Dimensiones 15 × 15 × 15 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet

Customers reviews

There are no reviews yet.

Be the first to review “LC1D50R7, contactor TeSys Deca – 3 poles – AC-3 440V 50 A – coil 440V AC”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart