TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Comprar Ahora
SKU: LC1D65M7

IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

LC1D65M7

Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
contactor application Motor control
Resistive load
Utilisation category AC-1
AC-2
AC-4
AC-3e
AC-1
poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 65 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
65 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
80 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
50 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
Complementary
Motor power kW 30 kW at 380…400 V AC 50 Hz
37 kW at 500 V AC 50 Hz
37 kW at 660…690 V AC 50 Hz
18.5 kW at 220…230 V AC 50 Hz
30 kW at 415 V AC 50 Hz
37 kW at 1000 V AC 50 Hz (AC-3)
25 kW at 415 V AC 50 Hz (AC-3)
22 kW at 380…400 V AC 50 Hz (AC-3)
Maximum Horse Power Rating 10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phase motors
20 hp at 230/240 V AC 60 Hz for 3 phase motors
40 hp at 460/480 V AC 60 Hz for 3 phase motors
50 hp at 575/600 V AC 60 Hz for 3 phase motors
7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
3 hp at 115 V AC 60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 80 A (at 140.0000000000 °F (60 °C)) for power circuit
10 A (at 140.0000000000 °F (60 °C)) for control circuit
Irms rated making capacity 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1
140 A AC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for control circuit conforming to IEC 60947-5-1
Power dissipation per pole 6.4 W AC-1
4.2 W AC-3e
9.6 W AC-1
3.7 W AC-3
[Ui] rated insulation voltage Control circuit 600 V UL
Power circuit 600 V CSA
Power circuit 600 V UL IEC 60947-1
Control circuit 690 V IEC 60947-1
Power circuit 690 V CSA IEC 60947-1
Control circuit 600 V CSA
Overvoltage category III
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC 50/60 Hz
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz
0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz
Inrush power in VA 160 VA cos phi 0.75 (at 68.0000000000 °F (20 °C))
140 VA cos phi 0.75 (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
13 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 12…26 ms closing
4…19 ms opening
Maximum operating rate 3600 cyc/h 140.0000000000 °F (60 °C)
Connections – terminals Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: rigid
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: rigid without cable end
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) – cable stiffness: flexible without cable end
Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) – cable stiffness: flexible with cable end
Power circuit: screw terminals 2 0.004…0.02 in² (2.5…10 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: rigid
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mirror contact 1 NC IEC 60947-4-1
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Terminals description ISO n°1 (21-22)NC
(A1-A2)CO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation between NC and NO contacts
1.5 ms on de-energisation between NC and NO contacts
Mounting Support Plate
Plate
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
UL 508
IEC 60947-4-1
Product Certifications DNV
LROS (Lloyds register of shipping)
CCC
CSA
BV
UL
GL
GOST
UKCA
RINA
IP degree of protection IP2X VDE 0106
IP2X IEC 60529
Climatic withstand IACS E10 exposure to damp heat
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562.0000000000 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor closed 15 Gn for 11 ms)
Vibrations contactor opened 2 Gn, 5…300 Hz)
Vibrations contactor closed 4 Gn, 5…300 Hz)
Shocks contactor opened 10 Gn for 11 ms)
Height 5.0000000000 in (127 mm)
Width 3.0 in (75 mm)
Depth 4.7 in (119 mm)
Net Weight 3.09 lb(US) (1.4 kg)
Ordering and shipping details
Category US10I1222357
Discount Schedule 0I12
GTIN 3389110437287
Returnability Yes
Country of origin CZ
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.7 in (9.5 cm)
Package 1 Width 5.2 in (13.2 cm)
Package 1 Length 5.5 in (14.0 cm)
Package 1 Weight 3.190 lb(US) (1.447 kg)
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 5.9 in (15.0 cm)
Package 2 Width 11.8 in (30.0 cm)
Package 2 Length 15.7 in (40.0 cm)
Package 2 Weight 16.680 lb(US) (7.566 kg)
Contractual warranty
Warranty 18 months
Peso 1.447 kg
Dimensiones 13.2 × 14 × 9.5 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Technical Drawing
CAD
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC1D65M7, IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart