Contactor body,TeSys F,3P(3NO), AC-3, <=440V 1100A without coil
LC1F400
Range | TeSys |
---|---|
Product name | TeSys F |
Product or Component Type | Contactor |
Device short name | LC1F |
contactor application | Resistive load Motor control |
Utilisation category | AC-3 AC-1 AC-4 |
poles description | 3P |
power pole contact composition | 3 NO |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
[Ie] rated operational current | 500 A 104 °F (40 °C)) <= 440 V AC AC-1 400 A 131 °F (55 °C)) <= 440 V AC AC-3 |
Motor power kW | 185 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 380…400 V AC 50/60 Hz (AC-3) 220 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 257 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 220…240 V AC 50/60 Hz (AC-3) 280 kW at 660…690 V AC 50/60 Hz (AC-3) 75 kW at 400 V AC 50/60 Hz (AC-4) |
[Uc] control circuit voltage | 48…1000 V AC 40…400 Hz with LX1/LX9 coil 48…440 V DC with LX4 coil 100…250 V AC 50/60 Hz with LXE coil 100…380 V DC with LXE coil |
---|---|
[Uimp] rated impulse withstand voltage | 8 kV |
Overvoltage category | III |
[Ith] conventional free air thermal current | 500 A (at 104 °F (40 °C)) |
Irms rated making capacity | 4000 A AC conforming to IEC 60947-4-1 |
Rated breaking capacity | 3200 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 3600 A 104 °F (40 °C) – 10 s 2400 A 104 °F (40 °C) – 30 s 1700 A 104 °F (40 °C) – 1 min 1200 A 104 °F (40 °C) – 3 min 1000 A 104 °F (40 °C) – 10 min |
Associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V |
Average impedance | 0.26 mOhm – Ith 500 A 50 Hz |
[Ui] rated insulation voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
Power dissipation per pole | 65 W AC-1 42 W AC-3 |
Control circuit voltage limits | Operational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil Drop-out: 0.3…0.5 Uc AC 40…400 Hz with LX1/LX9 coil Operational: 0.85…1.1 Uc DC with LX4 coil Drop-out: 0.2…0.35 Uc DC with LX4 coil Operational: 85…275 V AC 50/60 Hz with LXE coil Drop-out: 0…60 V AC 50/60 Hz with LXE coil Operational: 85…418 V DC with LXE coil Drop-out: 0…45 V DC with LXE coil |
Heat dissipation | 14 W 2.2…5.5 W |
Operating time | 40…75 ms closing with LX1/LX9 coil 100…170 ms opening with LX1/LX9 coil 50…60 ms closing with LX4 coil 45…60 ms opening with LX4 coil 40…80 ms closing with LXE coil 6…54 ms opening with LXE coil |
Mounting Support | Plate |
Standards | JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 EN 60947-1 |
Product Certifications | CB ABS DNV RMRoS LROS (Lloyds register of shipping) BV RINA UL CSA UKCA |
Connections – terminals | Power circuit bar 2 30 x 5 mm Power circuit lugs-ring terminals 2 0.2 in² (150 mm²) Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end |
Tightening torque | Power circuit 309.8 lbf.in (35 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m) |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 1000…1150 VA, 40…400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 920…1140 VA (at 68 °F (20 °C))with LX4 coil 360…470 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 410…450 VA (at 68 °F (20 °C))with LXE coil |
Hold-in power consumption in VA | 12…18 VA, 40…400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 4…7.5 VA (at 68 °F (20 °C))with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 2.5…4.0 VA (at 68 °F (20 °C))with LXE coil |
Maximum operating rate | 2400 cyc/h 131 °F (55 °C) |
Compatibility code | LC1F |
IP degree of protection | IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106 |
---|---|
Protective treatment | TH |
Ambient Air Temperature for Operation | 23…131 °F (-5…55 °C) |
Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) |
Operating altitude | 9842.52 ft (3000 m) without derating |
Mechanical robustness | Vibrations contactor open1.5 Gn, 5…300 Hz Vibrations contactor closed5 Gn, 5…300 Hz Shocks contactor open6 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Height | 8.1 in (206 mm) |
Width | 8.4 in (213 mm) |
Depth | 8.6 in (219 mm) |
Net Weight | 17.6 lb(US) (8 kg) |
Category | US10I1222336 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3389110122114 |
Returnability | Yes |
Country of origin | CZ |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 10.236 in (26.000 cm) |
Package 1 Width | 9.646 in (24.500 cm) |
Package 1 Length | 12.795 in (32.500 cm) |
Package 1 Weight | 17.915 lb(US) (8.126 kg) |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 10 |
Package 2 Height | 29.528 in (75.000 cm) |
Package 2 Width | 23.622 in (60.000 cm) |
Package 2 Length | 31.496 in (80.000 cm) |
Package 2 Weight | 201.811 lb(US) (91.540 kg) |
Warranty | 18 months |
---|