8910DPA32V02, Contactor, Definite Purpose, 30A, 2 pole, 5HP at 230VAC, 1 phase, 110/120VAC coil at 50/60Hz, open
MXN $1,587.93MXN $1,587.93 (sin impuestos)×
LC1G225KUEN, Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 225A, 100-250VAC/DC coil
MXN $40,444.00 - (IVA Incluido) + Envío
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 225A 132kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 225A, 100-250VAC/DC coil
LC1G225KUEN
Range | TeSys |
---|---|
Range of Product | TeSys Giga |
Product or Component Type | Contactor |
Device short name | LC1G |
contactor application | Power switching Motor control |
Utilisation category | AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5 |
poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
[Ie] rated operational current | 330 A (at <104.0000000000 °F (40 °C)) at <= 1000 V AC-1 225 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC-3 |
[Uc] control circuit voltage | 100…250 V AC 50/60 Hz 100…250 V DC |
Control circuit voltage limits | Operational: 0.8 Uc Min…1.1 Uc Max (at <140.0000000000 °F (60 °C)) Drop-out: 0.1 Uc Max…0.45 Uc Min (at <140.0000000000 °F (60 °C)) |
[Uimp] rated impulse withstand voltage | 8 kV |
---|---|
Overvoltage category | III |
[Ith] conventional free air thermal current | 330 A (at 104.0000000000 °F (40 °C)) |
Rated breaking capacity | 2050 A at 440 V |
[Icw] rated short-time withstand current | 1.8 kA – 10 s 1.0 kA – 30 s 0.85 kA – 1 min 0.56 kA – 3 min 0.44 kA – 10 min |
Associated fuse rating | 250 A aM at <= 440 V for motor 200 A aM at <= 690 V for motor 400 A gG at <= 690 V |
Average impedance | 0.00015 Ohm |
[Ui] rated insulation voltage | 1000 V |
Power dissipation per pole | 20 W AC-1 – Ith 330 A 8 W AC-3 – Ith 225 A |
Compatibility code | LC1G |
Pole contact composition | 3 NO |
Auxiliary contact composition | 1 NO + 1 NC |
Motor power kW | 55 kW at 230 V AC 50/60 Hz (AC-3e) 110 kW at 400 V AC 50/60 Hz (AC-3e) 110 kW at 415 V AC 50/60 Hz (AC-3e) 132 kW at 440 V AC 50/60 Hz (AC-3e) 132 kW at 500 V AC 50/60 Hz (AC-3e) 160 kW at 690 V AC 50/60 Hz (AC-3e) 132 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 132 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 690 V AC 50/60 Hz (AC-3) 132 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 110 kW at 400 V AC 50/60 Hz (AC-4) 110 kW at 415 V AC 50/60 Hz (AC-4) 129 kW at 440 V AC 50/60 Hz (AC-4) 132 kW at 500 V AC 50/60 Hz (AC-4) 132 kW at 690 V AC 50/60 Hz (AC-4) 110 kW at 1000 V AC 50/60 Hz (AC-4) |
Maximum Horse Power Rating | 60 hp at 200/208 V 60 Hz 75 hp at 230/240 V 60 Hz 150 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz |
Irms rated making capacity | 2720 A at 440 V |
Coil technology | Built-in bidirectional peak limiting |
Safety reliability level | B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 8 Mcycles |
inrush power in VA (50/60 Hz, AC) | 540 VA |
inrush power in W (DC) | 380 W |
hold-in power consumption in VA (50/60 Hz, AC) | 12.4 VA |
hold-in power consumption in W (DC) | 7.8 W |
Operating time | 40…70 ms closing 15…50 ms opening |
Maximum operating rate | 600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4 |
Connections – terminals | Power circuit: bar 2 – busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003…0.004 in² (0.2…2.5 mm²) – cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004…0.004 in² (0.25…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008…0.002 in² (0.5…1.0 mm²) with cable end Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) – cable stiffness: solid stranded without cable end Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) – cable stiffness: flexible with cable end |
Connection pitch | 1.4 in (35 mm) |
Mounting Support | Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 |
Product Certifications | CB Scheme CCC cULus EAC CE UKCA EU-RO-MR by DNV-GL |
Tightening torque | 159.3 lbf.in (18 N.m) |
Height | 7.6 in (193 mm) |
Width | 4.3 in (108 mm) |
Depth | 7.6 in (193 mm) |
Net Weight | 7.9 lb(US) (3.6 kg) |
IP degree of protection | IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106 |
---|---|
Ambient Air Temperature for Operation | -13.0000000000…140.0000000000 °F (-25…60 °C) |
Ambient Air Temperature for Storage | -76.0000000000…176.0000000000 °F (-60…80 °C) |
Mechanical robustness | Vibrations 5…300 Hz 2 gn contactor open Vibrations 5…300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed |
color | Dark grey |
Protective treatment | TH |
Permissible ambient air temperature around the device | -40.0000000000…158.0000000000 °F (-40…70 °C) at Uc |
Category | US10I1222329 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3606481921956 |
Returnability | Yes |
Country of origin | US |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 10.039 in (25.500 cm) |
Package 1 Width | 6.693 in (17.000 cm) |
Package 1 Length | 12.598 in (32.000 cm) |
Package 1 Weight | 10.049 lb(US) (4.558 kg) |
Unit Type of Package 2 | S06 |
Number of Units in Package 2 | 6 |
Package 2 Height | 29.528 in (75.000 cm) |
Package 2 Width | 23.622 in (60.000 cm) |
Package 2 Length | 31.496 in (80.000 cm) |
Package 2 Weight | 85.209 lb(US) (38.650 kg) |
Peso | 4.772 kg |
---|---|
Dimensiones | 23.5 × 38.5 × 24.5 cm |
Marcas | Schneider Electric |