LC2D09F7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 110V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D09F7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 4kW@400V. It includes a 110V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 110V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 9A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.

Comprar Ahora
SKU: LC2D09F7

TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 110 V AC coil

LC2D09F7

Main
Range TeSys
TeSys Deca
Product name TeSys D
TeSys Deca
Product or Component Type Reversing contactor
Device short name LC2D
contactor application Resistive load
Motor control
Utilisation category AC-1
AC-3
AC-3e
device presentation Preassembled with reversing power busbar
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 9 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
25 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
Motor power kW 2.2 kW at 220…230 V AC 50-60 Hz
4 kW at 380…400 V AC 50-60 Hz
4 kW at 415 V AC 50-60 Hz
4 kW at 440 V AC 50-60 Hz
5.5 kW at 500 V AC 50-60 Hz
5.5 kW at 660…690 V AC 50-60 Hz
motor power HP (UL / CSA) 0.5 hp at 115 V AC 60 Hz for 1 phase motors
1 hp at 230/240 V AC 60 Hz for 1 phase motors
2 hp at 200/208 V AC 60 Hz for 3 phase motors
2 hp at 230/240 V AC 60 Hz for 3 phase motors
5 hp at 460/480 V AC 60 Hz for 3 phase motors
7.5 hp at 575/600 V AC 60 Hz for 3 phase motors
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 140.0000000000 °F (60 °C)) for signalling circuit
25 A (at 140.0000000000 °F (60 °C)) for power circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 30 A 104.0000000000 °F (40 °C) – 10 min for power circuit
61 A 104.0000000000 °F (40 °C) – 1 min for power circuit
105 A 104.0000000000 °F (40 °C) – 10 s for power circuit
210 A 104.0000000000 °F (40 °C) – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Electrical durability 0.6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
Power dissipation per pole 0.2 W AC-3
1.56 W AC-1
0.2 W AC-3e
Front cover With
Interlocking type Mechanical
Mounting Support Rail
Plate
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product Certifications DNV
CSA
CCC
UL
GL
LROS (Lloyds register of shipping)
BV
RINA
GOST
UKCA
Connections – terminals Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Power circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid
Power circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid
Tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Operating time 12…22 ms closing
4…19 ms opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 15 Mcycles
Maximum operating rate 3600 cyc/h 140.0000000000 °F (60 °C)
Complementary
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C))
70 VA 50 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
7 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
Heat dissipation 2…3 W 50/60 Hz
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit
Environment
IP degree of protection IP20 front face IEC 60529
Climatic withstand IACS E10
IEC 60947-1 Annex Q category D
Protective treatment TH IEC 60068-2-30
Pollution degree 3
Ambient air temperature for operation -40.0000000000…140.0000000000 °F (-40…60 °C)
140.0000000000…158.0000000000 °F (60…70 °C) with derating
Ambient Air Temperature for Storage -76.0000000000…176.0000000000 °F (-60…80 °C)
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562.0000000000 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open2 Gn, 5…300 Hz
Vibrations contactor closed4 Gn, 5…300 Hz
Shocks contactor open10 Gn for 11 ms
Shocks contactor closed15 Gn for 11 ms
Height 3.03 in (77 mm)
Width 3.5 in (90 mm)
Depth 3.4 in (86 mm)
Net Weight 1.515 lb(US) (0.687 kg)
Ordering and shipping details
Category US10I1222354
Discount Schedule 0I12
GTIN 3389110383386
Returnability Yes
Country of origin ID
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.449 in (11.300 cm)
Package 1 Width 3.740 in (9.500 cm)
Package 1 Length 5.315 in (13.500 cm)
Package 1 Weight 28.571 oz (810.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 6
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 11.471 lb(US) (5.203 kg)
Contractual warranty
Warranty 18 months
Peso 0.81 kg
Dimensiones 11.3 × 13.8 × 9.3 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC2D09F7, TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A - 110 V AC coil”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart