LC2K0901F7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 110V 50/60Hz AC coil, 2NC auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K0901F7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 110V 50/60Hz AC coil and 2NC built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 110V AC coil compatible 50/60Hz and 2NC built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Comprar Ahora
SKU: LC2K0901F7

Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 110VAC coil

LC2K0901F7

Main
Range TeSys
Product name TeSys K
Product or Component Type Reversing contactor
Device short name LC2K
Device Application Control
contactor application Resistive load
Motor control
Utilisation category AC-3
AC-3e
AC-4
AC-1
device presentation Preassembled with reversing power busbar
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit 690 V AC 50/60 Hz
Signalling circuit <= 690 V AC 50/60 Hz
[Ie] rated operational current 9 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
9 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
20 A (at <140.0000000000 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Motor power kW 2.2 kW 220…230 V AC 50/60 Hz
4 kW 380…415 V AC 50/60 Hz
4 kW 440/690 V AC 50/60 Hz
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Auxiliary contact composition 1 NC
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140.0000000000 °F (60 °C)) for power circuit
10 A (at 122.0000000000 °F (50 °C)) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 122.0000000000 °F (50 °C) – 1 s for power circuit
85 A 122.0000000000 °F (50 °C) – 5 s for power circuit
80 A 122.0000000000 °F (50 °C) – 10 s for power circuit
60 A 122.0000000000 °F (50 °C) – 30 s for power circuit
45 A 122.0000000000 °F (50 °C) – 1 min for power circuit
40 A 122.0000000000 °F (50 °C) – 3 min for power circuit
20 A 122.0000000000 °F (50 °C) – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
Electrical durability 1.3 Mcycles 9 A AC-3 <= 440 V
1.3 Mcycles 9 A AC-3e <= 440 V
0.16 Mcycles 20 A AC-1 <= 690 V
0.02 Mcycles 54 A AC-4 <= 440 V
Interlocking type Mechanical
Mounting Support Plate
Rail
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product Certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Connections – terminals screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Tightening torque 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
Operating time 10…20 ms coil energisation and NO closing
10…20 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 5 Mcycles
Maximum operating rate 3600 cyc/h
Complementary
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <122.0000000000 °F (50 °C))
Drop-out: 0.2…0.75 Uc (at <122.0000000000 °F (50 °C))
Inrush power in VA 30 VA (at 68.0000000000 °F (20 °C))
Hold-in power consumption in VA 4.5 VA (at 68.0000000000 °F (20 °C))
Heat dissipation 1.3 W
Auxiliary contacts type Instantaneous 1 NC
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non overlap distance 0.02 in (0.5 mm)
Insulation resistance > 10 MOhm for signalling circuit
Environment
IP degree of protection IP20 VDE 0106
Protective treatment TC IEC 60068
TC DIN 50016
Ambient Air Temperature for Operation -13.0000000000…122.0000000000 °F (-25…50 °C)
Ambient Air Temperature for Storage -58.0000000000…176.0000000000 °F (-50…80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6
Vibrations contactor opened2 Gn, 5…300 Hz IEC 60068-2-6
Height 2.3 in (58 mm)
Width 3.5 in (90 mm)
Depth 2.2 in (57 mm)
Net Weight 0.86 lb(US) (0.39 kg)
Ordering and shipping details
Category US10I1222327
Discount Schedule 0I12
GTIN 3389110491906
Returnability Yes
Country of origin US
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.559 in (6.500 cm)
Package 1 Width 3.622 in (9.200 cm)
Package 1 Length 2.362 in (6.000 cm)
Package 1 Weight 12.945 oz (367.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 25
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 21.054 lb(US) (9.550 kg)
Contractual warranty
Warranty 18 months
Peso 0.364 kg
Dimensiones 6.5 × 9.2 × 6 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LC2K0901F7, Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 110VAC coil”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart