TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Profibus DP protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 1.35 to 27 amperes. 120 to 240 VAC is used to power this controller. Controller is 2.40 inches tall, 3.58 inches wide and 4.82 inches deep. Controller weighs 1.17 lbs. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Comprar Ahora
SKU: LTMR27PFM

Motor controller, TeSys T, Motor Management, Profibus DP, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC

LTMR27PFM

Main
Range TeSys
Product name TeSys T
Device short name LTMR
Product or Component Type Motor controller
Device Application Equipment monitoring and control
Measurement current 1.35…27 A
[Us] rated supply voltage 100…240 V AC 50/60 Hz
Current Consumption 8…62.8 mA
Supply voltage limits 93.5…264 V AC
Communication Port Protocol Profibus DP
Bus type Profibus DP polarised 2-wire RS485 1…125 9.6 kbit/s…12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A
Profibus DP polarised 2-wire RS485 1…125 9.6 kbit/s…12 Mbit/s, terminal block 2 shielded twisted pairs, type A
Complementary
[Ui] rated insulation voltage 690 V EN/IEC 60947-1
690 V CSA C22.2 No 14
690 V UL 508
[Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs EN/IEC 60947-4-1
6 kV current or voltage measurement circuit EN/IEC 60947-4-1
0.8 kV communication circuit EN/IEC 60947-4-1
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Associated fuse rating 4 A gG output
0.5 A gG control circuit
Protection Type Load fluctuation
Thermal protection
Locked rotor
Reverse polarity protection
Phase unbalance
Earth-leakage protection
Overload (long time)
Thermal overload protection
Overload
Phase failure
Power factor variation
Network and machine diagnosis type Phase fault and earth fault trip counters
Trip history information
Trip context information
Motor control command recording
Running hours counter/operating time
Waiting time after overload tripping
Remaining operating time before overload tripping
Fault recording
Starting current and time
Event recording
Logic input number 6
Input current 3.1 mA 100 V
7.5 mA 240 V
Current state 0 guaranteed Logic input 0…40 V <= 15 mA 25 ms
Current state 1 guaranteed Logic input 79…264 V >= 2 mA 25 ms
maximum output switching frequency 2 Hz
Load current 5 A 250 V AC logic output
5 A 30 V DC logic output
Permissible power 480 VA AC-15), Ie = 2 A, 500000 cycles output)
30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Maximum operating rate 1800 cyc/h
Contacts type and composition 1 NO + 1 NC fault signal
3 NO
Metering type Average current Iavg
Temperature
Earth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Measurement accuracy 5…15 % earth fault current internal measurement
1 % voltage 100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 Temperature
1 % current
5 % active and reactive power
Overvoltage category III
Connection pitch 0.20 in (5.08 mm)
Connections – terminals Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24…AWG 14)solid without cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)flexible with cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24…AWG 14)flexible without cable end
Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24…AWG 14)solid without cable end
Tightening torque Control circuit 4.4…5.3 lbf.in (0.5…0.6 N.m) flat 0.1 in (3 mm)
Pollution degree 3
Electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width 3.6 in (91 mm)
Height 2.4 in (61 mm)
Depth 4.8 in (122.5 mm)
Net Weight 1.17 lb(US) (0.53 kg)
Web services Web server
Compatibility code LTMR
Environment
Standards EN 60947-4-1
UL 508
IACS E10
CSA C22.2 No 14
IEC 60947-4-1
Product Certifications BV
CSA
CCC
EAC
NOM
KERI
ABS
RMRoS
LROS (Lloyds register of shipping)
UL
RINA
DNV
GL
C-tick
ATEX
Protective treatment 12 x 24 hour cycles EN/IEC 60068-2-30
48 h EN/IEC 60070-2-11
TH EN/IEC 60068
Fire resistance 1202.0000000000 °F (650 °C) EN/IEC 60695-2-12
1760.0000000000 °F (960 °C) UL 94
Ambient air temperature for operation -4.0000000000…140.0000000000 °F (-20…60 °C)
Ambient Air Temperature for Storage -40.0000000000…176.0000000000 °F (-40…80 °C)
Operating altitude <= 6561.68 ft (2000 m) without derating
Mechanical robustness Vibrations mounted on symmetrical rail1 Gn, 5…300 Hz EN/IEC 60068-2-6
Vibrations plate mounted4 Gn, 5…300 Hz EN/IEC 60068-2-6
Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
IP Degree of Protection IP20
Ordering and shipping details
Category US10I1222338
Discount Schedule 0I12
GTIN 3389119404839
Returnability No
Country of origin CN
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.8 in (7.2 cm)
Package 1 Width 3.9 in (10.0 cm)
Package 1 Length 5.4 in (13.6 cm)
Package 1 Weight 18.5 oz (525.0 g)
Unit Type of Package 2 S02
Number of Units in Package 2 10
Package 2 Height 5.9 in (15.0 cm)
Package 2 Width 11.8 in (30.0 cm)
Package 2 Length 15.7 in (40.0 cm)
Package 2 Weight 12.315 lb(US) (5.586 kg)
Contractual warranty
Warranty 18 months
Peso 0.525 kg
Dimensiones 10 × 13.6 × 7.2 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
User guide
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LTMR27PFM, Motor controller, TeSys T, Motor Management, Profibus DP, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
MXN Peso mexicano
Product has been added to your cart