TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 1.5kW@400V. It provides full protection to motors with a rated current Ir 1.25-5A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

SKU: LUCA05FU

Standard control unit, TeSys Ultra, 1.25A to 5A, class 10, 110 to 220VDC/AC

LUCA05FU

Main
Range TeSys
Range of Product TeSys Ultra
Product name TeSys Ultra
Device short name LUCA
Product or Component Type Standard control unit
Device Application Motor control
Motor protection
Product Specific Application Basic protection requirements for motor starters: overload and short-circuit
main function available Protection against phase failure and phase imbalance
Protection against overload and short-circuit
Manual reset
Earth fault protection
Product compatibility Power base LUB12
Power base LUB32
Power base LUB38
Power base LUB120
Power base LUB320
Power base LUB380
Reversing contactor breaker LU2B12FU
Reversing contactor breaker LU2B32FU
Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage 690 V AC
Network frequency 40…60 Hz
Load type 3-phase motor self-cooled
Utilisation category AC-44
AC-41
AC-43
Motor power kW 1.5 kW 400…440 V AC 50/60 Hz
2.2 kW 500 V AC 50/60 Hz
3 kW 690 V AC 50/60 Hz
rated motor current adjustment range 1.25…5 A
Thermal overload class Class 10 40…60 Hz -13…158 °F (-25…70 °C) IEC 60947-6-2
Class 10 40…60 Hz -13…158 °F (-25…70 °C) UL 508
Tripping threshold 14.2 x Ir +/- 20 %
Phase failure sensitivity Yes
[Uc] control circuit voltage 110…240 V AC
110…220 V DC
Complementary
Control circuit voltage limits 88…264 V AC 110…240 V in operation
88…242 V DC 110…220 V in operation
55 V AC 110…240 V drop-out
55 V DC 110…220 V drop-out
Typical current consumption 280 mA 110…240 V AC I maximum while closing with LUB12
280 mA 110…240 V AC I maximum while closing with LUB32
280 mA 110…240 V AC I maximum while closing with LUB38
280 mA 110…220 V DC I maximum while closing with LUB12
280 mA 110…220 V DC I maximum while closing with LUB32
280 mA 110…220 V DC I maximum while closing with LUB38
35 mA 110…240 V AC I rms sealed with LUB12
25 mA 110…240 V AC I rms sealed with LUB32
25 mA 110…240 V AC I rms sealed with LUB38
35 mA 110…220 V DC I rms sealed with LUB12
25 mA 110…220 V DC I rms sealed with LUB32
25 mA 110…220 V DC I rms sealed with LUB38
Heat dissipation 2 W control circuit with LUB12
3 W control circuit with LUB32
3 W control circuit with LUB38
Operating time 35 ms opening with LUB12 control circuit
35 ms opening with LUB32 control circuit
35 ms opening with LUB38 control circuit
50 ms closing with LUB12 control circuit
50 ms closing with LUB32 control circuit
50 ms closing with LUB38 control circuit
Standards EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
Product Certifications CE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
[Ui] rated insulation voltage 690 V IEC 60947-6-2
600 V UL 60947-4-1
600 V CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-6-2
Safe separation of circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing mode Plug-in (front face)
Width 1.8 in (45 mm)
Height 2.6 in (66 mm)
Depth 2.4 in (60 mm)
Net Weight 0.298 lb(US) (0.135 kg)
Compatibility code LUCA
Environment
IP degree of protection IP20 front panel and wired terminals IEC 60947-1
IP20 other faces IEC 60947-1
IP40 front panel outside connection zone IEC 60947-1
Protective treatment TH IEC 60068
Ambient air temperature for operation -13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Operating altitude 6561.68 ft (2000 m)
Fire resistance 1760 °F (960 °C) parts supporting live components IEC 60695-2-12
1202 °F (650 °C) IEC 60695-2-12
Shock resistance 10 gn power poles open IEC 60068-2-27
15 gn power poles closed IEC 60068-2-27
Vibration resistance 2 gn 5…300 Hz power poles open IEC 60068-2-6
4 gn 5…300 Hz power poles closed IEC 60068-2-6
Resistance to electrostatic discharge 8 kV 3 in open air IEC 61000-4-2
8 kV 4 on contact IEC 61000-4-2
Non-dissipating shock wave 1 kV serial mode IEC 60947-6-2
2 kV common mode IEC 60947-6-2
Resistance to radiated fields 9.1 V/m (10 V/m) 3 IEC 61000-4-3
Resistance to fast transients 2 kV 3 serial link IEC 61000-4-4
4 kV 4 all circuits except for serial link IEC 61000-4-4
Immunity to radioelectric fields 10 V IEC 61000-4-6
Immunity to microbreaks 3 ms
Immunity to voltage dips 70 % / 500 ms IEC 61000-4-11
Ordering and shipping details
Category US10I1122397
Discount Schedule 0I11
GTIN 3389110364026
Returnability Yes
Country of origin FR
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.465 in (8.800 cm)
Package 1 Width 3.228 in (8.200 cm)
Package 1 Length 2.047 in (5.200 cm)
Package 1 Weight 4.021 oz (114.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 23
Package 2 Height 5.906 in (15.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 6.548 lb(US) (2.970 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 368
Package 3 Height 30.315 in (77.000 cm)
Package 3 Width 31.496 in (80.000 cm)
Package 3 Length 23.622 in (60.000 cm)
Package 3 Weight 123.503 lb(US) (56.020 kg)
Contractual warranty
Warranty 18 months
Peso 0.114 kg
Dimensiones 8.2 × 5.2 × 8.8 cm
Marcas

Schneider Electric

Marca

Schneider Electric

Product Datasheet
Instruction Sheet
Catalog
Environmental Disclosure

Customers reviews

There are no reviews yet.

Be the first to review “LUCA05FU, Standard control unit, TeSys Ultra, 1.25A to 5A, class 10, 110 to 220VDC/AC”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Search for products

Back to Top
Elegir Moneda
USD Dólar de los Estados Unidos (US)
Product has been added to your cart